Samsung SR-65NMC, SR-65KTC, SR-69NMC, SR-61KTC, SR-61NMC specifications

Models: SR-61NMC SR-61KTC SR-69NMC SR-65NMC SR-65KTC

1 80
Download 80 pages 369 b
Page 21
Image 21
ITEM

E. self diagnosis function

1)Power on refrigerator and it run seif diagnosis function about 2 seconds at the inner part.

2)If no preblem it turns normal mode.

3)If find prebiem display lamp of PCB show errw position like lower list and everything dont operate until repair error position.

4)After refrigerator power off and then power on for confirming conditiom.

5)Thus if you want to know OPEN/SHORT of temperature sensor on SVC, power off and on if it run self diagnosis function.

6)When error occur LAMP display method.(Lamp on time : 0.3 seconds ( ON/OFF) Lamp off time : 2 seconds)

No.

ITEM

Led Display

Problem

Remark

 

 

 

 

 

 

1

F DEFROST

On

-.OPEN ERROR

-. SENSOR IS BELOW -50

SENSOR

Off

-.SHORT ERROR

-. SENSOR IS BELOW +50

 

 

 

 

 

 

 

2

R DEFROST

On

-.OPEN ERROR

-. SENSOR IS BELOW - 50

Off

-.SHORT ERROR

-. SENSOR IS BELOW +50

SENSOR

 

3

F SENSOR

On

-.OPEN ERROR

-. SENSOR IS BELOW - 50

Off

-.SHORT ERROR

-. SENSOR IS BELOW +50

 

 

 

 

 

 

 

 

4

R SENSOR

On

-.OPEN ERROR

-. SENSOR IS BELOW - 50

Off

-.SHORT ERROR

-. SENSOR IS BELOW +50

 

 

 

 

 

 

 

 

5

F Rotary S/W

On

-.OPEN ERROR

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

6

R Rotary S/W

On

-.OPEN ERROR

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

7

NORMAL MODE

On

 

Vntil operating initial 5minutes

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In case of many problems find it display error position in order. <Example of error display>

When problem R-ROOM SENSOR display lamp operating.

(0.3 seconds ; ON/OFF) Four times 2 seconds OFF - REPEAT -

When problem R-ROOM SENSOR and F-ROOM sensor at the same time display method. (0.3 seconds ; ON/OFF) Three times 2 seconds OFF - REPEAT -

Tem perature contre control operating by ROTRAY SWITCH

 

INITIAL SEIF DIAGNOSIS(OFF/ON)

OPERATING

OPEN ERROR

STOP ERROR DISPLAY OPERATING

OPERATING BEFORE OPEN STEP

 

 

 

SHORT ERROR

HIGH

HIGH”

SECTION

MID

OPERATING BEFORE SETTING UP STEP

F. Quick heating operating

1)If freezer heating sensor OPEN/SHORT error at freezer heating it runs just rest time without heating..

2)If refrigerator heating sensor OPEN/SHORT error at refrigerator heating it runs jest time without heating.

21