Samsung SR-65KTC, SR-65NMC Comp And Defrosting Heater Operating, States, Load, Remark, -24-

Models: SR-61NMC SR-61KTC SR-69NMC SR-65NMC SR-65KTC

1 80
Download 80 pages 369 b
Page 25
Image 25
7. COMP AND DEFROSTING HEATER OPERATING

7. COMP AND DEFROSTING HEATER OPERATING

GRY

RED

COMP LED

F-DEFROSTING HEATER

R-DEFROSTING HEATER

As it is seen above block diagram. 220V line is connected to the commons of comp relay, Ry 71 and defrosting heater relay, Ry 73, Ry 75. When those relays are off state comp and defrosting heater are also off. As comp relay moves to on and AC 220V applied to comp load it starts operating On the other hand defrost heater runs if defrost heater relay moves to on. There is no chance that both comp and defrost heater runs together so its useful for safety aspect.

 

 

 

 

 

 

 

 

 

 

 

STATES

 

 

 

 

 

 

 

 

 

 

LOAD

 

 

REMARK

 

 

 

 

 

 

 

 

 

COMP

 

F DEFROSTING HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

 

COMP OPERATION

preverting power of F-DEFROSTING HEATER

 

 

 

 

 

 

 

ON

 

ON

COMP OFF, F-DEFROSTING HEATER OFF

 

 

 

 

 

 

 

 

 

 

OFF

 

ON

 

F-DEFROSTING HEATER ON

 

PREVENTING COMP POWER

 

 

 

 

 

 

 

OFF

 

OFF

COMP OFF, F-DEFROSTING HEATER OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

24

Page 25
Image 25