To install the drain hose, proceed as follows.

INSTALLING THE INDOOR UNIT

Installing and Connecting the Indoor Unit Drain Hose

ENGLISH

Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through

the 65mm( 2 169 inch) hole drilled in the wall, check that none of the following situations occur.

The hose must

The end of the drain

Do NOT bend the

NOT slope

hose must NOT be

hose in different

upwards.

placed in water.

directions.

 

 

 

5cm

(2inch)

less

Keep a clearance of at least 5cm(2inch) between the end of the hose and the ground.

Manual background Ditch

Do NOT place the end of the drain hose in a hollow.

To install the drain hose, proceed as follows.

1If necessary, connect the 2m(6ft. 7in) extension to the drain hose.

2If you are using the extension, insulate the inside part of the extension drain hose with a shield.

3Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight.

4Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as shown in the illustrations above.

The hose will be fixed permanently into position once the whole installation has been tested for gas leaks; refer to page 47 for further details.

Shield

 

Drain hose

Extension drain hose