Sankyo 11AR manual Indexing time vs. stops chart, Data switch settings, Unit

Models: 11AR

1 34
Download 34 pages 57.38 Kb
Page 23
Image 23
5.5 Indexing time vs. stops chart

Unit 5

Operation

5.5 Indexing time vs. stops chart

Index time- # Stops chart

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time in

1.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Index

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

# Stops

 

 

 

 

 

 

 

5.6 Data switch settings

Program#

 

Data

 

Stops

Index Angle

Index time

3 bit

2 bit

1bit

0bit

[degree]

[sec]

 

 

0

 

 

 

 

1

360

3.172

1

 

 

 

On

2

180

1.636

2

 

 

On

 

3

120

1.124

3

 

 

On

On

4

90

0.868

4

 

On

 

 

5

72

0.714

5

 

On

 

On

6

60

0.612

6

 

On

On

 

7

51.42857

0.539

7

 

On

On

On

8

45

0.484

8

On

 

 

 

9

40

0.441

9

On

 

 

On

10

36

0.407

10

On

 

On

 

11

32.72727

0.379

11

On

 

On

On

12

30

0.356

12

On

On

 

 

13

27.69230

0.336

13

On

On

 

On

14

25.71428

0.319

14

On

On

On

 

15

24

0.305

15

On

On

On

On

16

22.5

0.292

22

Page 23
Image 23