– 19 –
SM830092
5. PERFORMANCE CHARTS
230V / 208 V Low Pressure

Low pressure characteristics versus outdoor ambient temperature and indoor temperature.

(Indoor relative humidity: 50%, Indoor fan speed: High)
(2) High and Low Pressure
1Indoor Unit: KS2462R Outdoor Unit: C2462R
High Pressure

High pressure characteristics versus outdoor ambient temperature and indoor temperature.

(Indoor relative humidity: 50%, Indoor fan speed: High)
1065_X_S
85 (30)
80 (27)
75 (24)
70 (21)

Discharge pressure (psig)

440
460
480
360
340
380
400
420
320
30059 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
Indoor
temp.
°F (°C)
Outdoor fan speed
Low High
1066_X_S
Indoor
temp.
°F (°C)
Outdoor fan speed
Low High
Suction pressure (psig)
140
130
150
160
170
120
11059 68 77 86 95 104
(15) (20) (25) (30) (35) (40)
Outdoor ambient temp. °F (°C)
85 (30)
80 (27)
75 (24)
70 (21)
230V / 208 V