Sanyo CL2462R, C2462R service manual Unit Specifications

Models: C2462R CL2462R

1 58
Download 58 pages 31.12 Kb
Page 5
Image 5

2. SPECIFICATIONS

1-1 Unit Specifications

 

MODEL No.

 

Indoor Unit

 

 

 

 

KS2462R

 

 

 

 

Outdoor Unit

 

 

 

 

C2462R

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

PERFORMANCE

 

 

 

 

 

Cooling

 

 

Capacity

 

BTU / h

 

27,000

 

26,000

 

 

 

 

 

kW

 

7.912

 

7.619

 

 

Air circulation (Hi)

 

Cu.ft. / min.

 

559

 

 

519

 

 

Moisture removal (High)

 

Pints / h

 

6.5

 

 

6.4

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

 

230

 

 

208

 

 

Available voltage range

 

 

VAC

 

 

187 – 253

 

 

Running amperes*

 

 

A

 

10.2

 

 

10.9

 

 

Max. running amperes**

 

 

A

 

12.5

 

 

13.5

 

 

Power input

 

 

W

 

2,240

 

2,200

 

 

Power factor

 

 

%

 

95.5

 

 

97.0

 

 

S.E.E.R

 

BTU / Wh

 

13.0

 

 

13.0

 

 

Max. starting amperes

 

 

A

 

61

 

 

61

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

 

Microprocessor

 

 

Timer

 

 

 

 

ON/OFF 24-hours & Program

 

 

Fan speed Indoor / Outdoor

 

 

 

 

3 and Automatic control / 2 (Auto)

 

 

Air deflection

Horizontal / Vertical

 

 

– / Automatic

 

 

Air filter

 

 

 

 

 

Washable, easy access

 

 

Remote controller (Accessory)

 

 

 

 

RCS - 1PS4U - G

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

Refrigerant tubing connections

 

 

 

 

Flare type

 

 

Compressor

 

 

 

 

 

Scroll

 

 

Operation sound

Indoor - Hi/Me/Lo

dB - A

 

 

48 / 42 / 38

 

 

 

 

Outdoor - Hi

dB - A

 

 

 

55

 

 

REFRIGERANT TUBING

 

 

 

 

 

 

 

 

 

 

Limit of tubing length

 

ft.

(m)

 

 

132 ( 40 )

 

 

Limit of tubing length at shipment

ft.

(m)

 

 

23 ( 7 )

 

 

Limit of elevation difference

 

ft.

(m)

 

 

50 ( 15 )

 

 

between the two units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant tube

Narrow tube

in. (mm)

 

 

3 / 8

(9.52)

 

 

outer diameter

Wide tube

in. (mm)

 

 

3 / 4

(19.05)

 

 

Refrigerant amount at shipment

lbs. (kg)

 

 

R410A - 6.6 (3)

 

 

DIMENSIONS & WEIGHT

 

 

 

 

Indoor unit

 

Outdoor unit

 

Unit dimensions

Height

in. (mm)

 

13

(330)

 

36-5/8

(930)

 

 

 

Width

in. (mm)

 

44-7/8

(1,140)

 

37

(940)

 

 

 

Depth

in. (mm)

 

8-31/32

(228)

 

13-3/8

(340)

 

Package dimensions

Height

in. (mm)

 

12-25/32

(325)

 

39-3/4

(1,010)

 

 

 

Width

in. (mm)

 

48-15/32

(406)

 

39-3/8

(1,000)

 

 

 

Depth

in. (mm)

 

15-31/32

(406)

 

15-3/4

(400)

 

Net weight

 

lbs. (kg)

 

40

(18)

 

150

(68)

 

Shipping weight

 

lbs. (kg)

 

44

(20)

 

190

(86.5)

 

Shipping volume

 

cu. ft.(m3)

 

5.7

(0.162)

 

14.1

(0.40)

Cooling:

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

 

 

Rating conditions (*) : Indoor air temperature 80 °F DB / 67 °F WB,

Outdoor air temperature 95 °F DB / 75°F WB

 

 

Full load conditions (**): Indoor air temperature 80 °F DB / 67 °F WB,

Outdoor air temperature 115 °F DB

 

SM830092

– 5 –

Page 5
Image 5
Sanyo CL2462R, C2462R service manual Unit Specifications