![](/images/new-backgrounds/1044801/448019x1.webp)
2. SPECIFICATIONS
1-1 Unit Specifications
| MODEL No. |
| Indoor Unit |
|
|
|
| KS2462R |
| ||
|
|
| Outdoor Unit |
|
|
|
| C2462R |
| ||
| POWER SOURCE |
|
|
|
| 230 - 208 V / 1 Phase / 60 Hz |
| ||||
| PERFORMANCE |
|
|
|
|
| Cooling |
| |||
| Capacity |
| BTU / h |
| 27,000 |
| 26,000 | ||||
|
|
|
|
| kW |
| 7.912 |
| 7.619 |
| |
| Air circulation (Hi) |
| Cu.ft. / min. |
| 559 |
|
| 519 |
| ||
| Moisture removal (High) |
| Pints / h |
| 6.5 |
|
| 6.4 |
| ||
| ELECTRICAL RATINGS |
|
|
|
|
|
|
|
|
| |
| Voltage rating |
|
| VAC |
| 230 |
|
| 208 |
| |
| Available voltage range |
|
| VAC |
|
| 187 – 253 |
| |||
| Running amperes* |
|
| A |
| 10.2 |
|
| 10.9 |
| |
| Max. running amperes** |
|
| A |
| 12.5 |
|
| 13.5 |
| |
| Power input |
|
| W |
| 2,240 |
| 2,200 |
| ||
| Power factor |
|
| % |
| 95.5 |
|
| 97.0 |
| |
| S.E.E.R |
| BTU / Wh |
| 13.0 |
|
| 13.0 |
| ||
| Max. starting amperes |
|
| A |
| 61 |
|
| 61 |
| |
| FEATURES |
|
|
|
|
|
|
|
|
| |
| Controls |
|
|
|
|
| Microprocessor |
| |||
| Timer |
|
|
|
| ON/OFF |
| ||||
| Fan speed Indoor / Outdoor |
|
|
|
| 3 and Automatic control / 2 (Auto) |
| ||||
| Air deflection | Horizontal / Vertical |
|
|
| ||||||
| Air filter |
|
|
|
|
| Washable, easy access |
| |||
| Remote controller (Accessory) |
|
|
|
| RCS - 1PS4U - G |
| ||||
| Refrigerant control |
|
|
|
|
| Capillary tube |
| |||
| Refrigerant tubing connections |
|
|
|
| Flare type |
| ||||
| Compressor |
|
|
|
|
| Scroll |
| |||
| Operation sound | Indoor - Hi/Me/Lo | dB - A |
|
| 48 / 42 / 38 |
| ||||
|
|
| Outdoor - Hi | dB - A |
|
|
| 55 |
| ||
| REFRIGERANT TUBING |
|
|
|
|
|
|
|
|
| |
| Limit of tubing length |
| ft. | (m) |
|
| 132 ( 40 ) |
| |||
| Limit of tubing length at shipment | ft. | (m) |
|
| 23 ( 7 ) |
| ||||
| Limit of elevation difference |
| ft. | (m) |
|
| 50 ( 15 ) |
| |||
| between the two units |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
| Refrigerant tube | Narrow tube | in. (mm) |
|
| 3 / 8 | (9.52) |
| |||
| outer diameter | Wide tube | in. (mm) |
|
| 3 / 4 | (19.05) |
| |||
| Refrigerant amount at shipment | lbs. (kg) |
|
| R410A - 6.6 (3) |
| |||||
| DIMENSIONS & WEIGHT |
|
|
|
| Indoor unit |
| Outdoor unit | |||
| Unit dimensions | Height | in. (mm) |
| 13 | (330) |
| (930) | |||
|
|
| Width | in. (mm) |
| (1,140) |
| 37 | (940) | ||
|
|
| Depth | in. (mm) |
| (228) |
| (340) | |||
| Package dimensions | Height | in. (mm) |
| (325) |
| (1,010) | ||||
|
|
| Width | in. (mm) |
| (406) |
| (1,000) | |||
|
|
| Depth | in. (mm) |
| (406) |
| (400) | |||
| Net weight |
| lbs. (kg) |
| 40 | (18) |
| 150 | (68) | ||
| Shipping weight |
| lbs. (kg) |
| 44 | (20) |
| 190 | (86.5) | ||
| Shipping volume |
| cu. ft.(m3) |
| 5.7 | (0.162) |
| 14.1 | (0.40) | ||
Cooling: |
|
|
|
| DATA SUBJECT TO CHANGE WITHOUT NOTICE. | ||||||
|
|
|
|
|
|
|
|
| |||
| Rating conditions (*) : Indoor air temperature 80 °F DB / 67 °F WB, | Outdoor air temperature 95 °F DB / 75°F WB |
| ||||||||
| Full load conditions (**): Indoor air temperature 80 °F DB / 67 °F WB, | Outdoor air temperature 115 °F DB |
|
SM830092