Maintenance
When the life of the projection lamp draws to an end, LAMP REPLACE indicator lights yellow. If this indicator lights yellow, replace the projection lamp with a new one promptly.
This indicator lights yellow when the life of the projection lamp draws to an end.
TOP CONTROL
| WARNING |
POWER | LAMP |
| REPLACE |
INPU
CAUTION
Allow a projector to cool, for at least 45 minutes before you open Lamp Cover. The inside of a projector can become very hot.
For continued safety, replace with a lamp assembly of the same type.
Do not drop a lamp assembly or touch a glass bulb! The glass can shatter and may cause injury.
Follow these steps to replace the lamp assembly.
1 | Screw |
Turn off the projector and disconnect AC plug. Allow the | |
| projector to cool at least for 45 minutes. |
2 | To remove the lamp cover, remove the screw with a screwdriver . |
|
3 | Remove the two screws with a screwdriver and pull out the |
|
| lamp assembly by grasping the handle. |
|
4 | Replace the lamp assembly with a new one and tighten the two |
|
| screws back into the position. Make sure that the lamp |
|
| assembly is set properly. Replace the lamp cover and tighten |
|
| the screw. |
|
5 | Connect the AC Power Cord to the projector and turn on the |
|
| projector. |
|
6 | Reset the Lamp Replace Counter. |
|
| Refer to “Lamp Replace Counter” on the next page . | Screws |
|
| |
Note : |
| |
Do not reset the Lamp Replace Counter when the projection lamp has not |
| |
been replaced. |
|
Lamp Cover
Handle
Lamp Assembly
Replacement Lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.
| • | Model No. of your projector | : |
| |
| • | Replacement Lamp Type No. | : |
| |
|
|
|
| (Service Parts No. 610 308 3117) |
|
|
|
|
|
|
|
|
|
|
|
|
|
40