Sanyo PLC-XK2600 owner manual Lamp Replacement, Reset the lamp counter

Models: PLC-XK2600

1 77
Download 77 pages 36.55 Kb
Page 61
Image 61

Maintenance and Cleaning

Lamp Replacement

When the projection lamp of the projector reaches its end of life, the Lamp replacement icon appears on the screen and LAMP REPLACE indicator lights yellow.

Replace the lamp with a new one promptly. The timing when the LAMP REPLACE indicator should light is depending on the lamp mode.

Note:

Top Control

LAMP REPLACE indicator

Lamp replacement icon

The Lamp replacement icon will not appear when the Display function is set to Off (p.46), during Freeze (p.25), or No show (p.26).

CAUTION

Allow a projector to cool for at least 45 minutes before you open the Lamp Cover. The inside of the projector can become very hot.

CAUTION

For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.

CAUTION

When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be broken.

If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that the lamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp cover gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyes or mouth, seek medical advice immediately.

Follow these steps to replace the lamp.

1

Unplug the AC power cord. Let the projector cool for

at least 45 minutes.

2

Loosen the screw and open the lamp cover.

3

Loosen the three (3) screws that secure the lamp.

Lift the lamp out of the projector by using the

 

handles.

4

Replace the lamp with a new one and secure the

three (3) screws. Make sure that the lamp is set

 

properly. Close the lamp cover and secure the

 

screw.

5

Connect the AC power cord to the projector and turn

on the projector.

6

Reset the lamp counter.

See "Lamp Counter" on page 55.

Lamp Cover

Screw

Screw

HandlesScrew

Lamp

Screw

61