50
Chapter 4 Advanced setting
Command name Command Response Description
Power status check CR0 or CR STATUS
00 Power on
80 Stand-by
40 Count down
20 Cooling
Lamp status check CR LAMPSTS 00 Lamp On, only available for multiple lamps
model.
80, 40,20,10 Lamp off
Input source CR SOURCE
ANALOG Analog input
DIGITAL Digital input
S-VIDEO S-video input
VIDEO Video input
Input status CR SIGNAL ON Signal exists
OFF No signal
Input Select CR INPUT 1,2,3,4,5 Selected input mode
Temperature CR TEMP temperature Actual temperature
Lamp use time CR LAMPH time Lamp use time in hours
Projector use time CR PROJH time Accumulated use time in hours
Network board ver-
sion LR PJNETVERSION version number Firmware version of network board
Model Name CR MODELNM model name Model name, “PLC-XF60” etc.
Condition check commands and response* Some kinds of commands may not effective or may differ depending on each model. For further infor-
mation, please contact your sales dealer.