6. ELECTRICAL DATA
6-1. Electrical Characteristics
Model STB0810C1
Model STB1010C1
Model STB1020C1
Model STB1220C1
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 230 / 208V 1-phase 60Hz
Rating Conditions Running Amps. A0.61 /0.64 5.49 /5.96 6.1 /6.6
Power Input kW 0.142 /0.132 1.208 /1.198 1.35 /1.33
Full Load Conditions Running Amps. A0.61 /0.64 6.29 /6.96 6.9 /7.6
Power Input kW 0.142 /0.132 1.428 /1.438 1.57 /1.57
Rating Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 90°F (32.2°C) D.B. / 73°F (22.8°C) W.B.
Outdoor Air Temperature 110°F (43.3°C) D.B.
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 230 / 208V 1-phase 60Hz
Rating Conditions Running Amps. A0.61 /0.64 4.39 /4.66 5.0 /5.3
Power Input kW 0.142 /0.132 0.998 /0.978 1.14 /1.11
Full Load Conditions Running Amps. A0.61 /0.64 4.99 /5.26 5.6 /5.9
Power Input kW 0.142 /0.132 1.118 /1.098 1.26 /1.23
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 115V 1-phase 60Hz
Rating Conditions Running Amps. A1.26 9.34 10.6
Power Input kW 0.145 1.055 1.20
Full Load Conditions Running Amps. A1.26 11.04 12.3
Power Input kW 0.145 1.255 1.40
Outdoor Unit Complete Unit
Fan Motor Compressor
Performance at 115V 1-phase 60Hz
Rating Conditions Running Amps. A1.26 7.04 8.3
Power Input kW 0.145 0.795 0.94
Full Load Conditions Running Amps. A1.26 8.34 9.6
Power Input kW 0.145 0.935 1.08
Cooling only models
18