10. FUNCTION

10-1. Room Temperature Control

Room temperature control is obtained by cycling the compressor ON and OFF.

Cooling Only Model

Models STB0810C1 STB1010C1 STB1020C1 STB1220C1

Cooling

Thermo. ON : When the room temperature rises above T + 4°F (T°F is set temperature). Compressor ON

Thermo. OFF : When the room temperature falls below set temperature T°F. Compressor OFF

 

 

 

Room temp.

 

 

 

T+4 °F

 

 

 

 

set temp.

T °F

 

 

 

 

Compressor

ON

OFF

ON

OFF

 

 

 

 

Fan motor

 

Set speed

 

 

42