1
29
52
52
Download
52 pages, 1.34 Mb
25
Model
STB0823H1
To avoid electrical shock hazard, be sure to
disconnect power before checking, servicing
and/or cleaning any electrical parts.
WARNING
Contents
Main
TECHNICAL & SERVICE MANUAL
IMPORTANT! Please Read Before Starting
When Wiring
When Transporting
When Installing
When Servicing
STB 1 0 2 3 C 1
Table of Contents
1. OPERATING RANGE
2. SPECIFICATIONS
2-1. Unit Specifications
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1
Models STB0811C1 STB1023C1 STB1123C1 STB0823H1
2-2. Major Component Specifications
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1
Models STB0811C1 STB1023C1 STB1123C1 STB0823H1
2-3. Other Component Specifications
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1 STB0811C1 STB1023C1 STB1123C1 STB0823H1
3. DIMENSIONAL DATA
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1 STB0811C1 STB1023C1 STB1123C1 STB0823H1
Unit : inch
Dimension of Wall Opening
Front view
4. REFRIGERANT FLOW DIAGRAM
Models STB0810C1 STB1010C1 STB1020C1 STB1220C1 STB0811C1 STB1023C1 STB1123C1
5. PERFORMANCE DATA
5-1. Cooling Capacity
Model STB0810C1
Model STB1010C1
Model STB1020C1
Model STB1220C1
Page
Model STB1023C1
Model STB1123C1
Page
5-2. Heating Capacity (Heat pump Performance)
100
Outdoor ambient temperature (F DB)
Heating capacity ratio (%)
47
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Model STB0810C1
Model STB1010C1
Model STB1020C1
Model STB1023C1
Model STB1123C1
Cooling & electric heating models
Heat pump model
6-2. Electrical Wiring Diagrams
Models STB0810C1 STB1010C1
Models STB1020C1 STB1220C1
Page
Models STB1023C1 STB1123C1
Page
WARNING
LAYOUT FOR ELECTRIC PARTS
Page
7. TROUBLESHOOTING
7-1. Check before and after troubleshooting
7-1-1. Check power supply.
7-1-2. Check lead wires and connectors.
7-2. Air conditioner does not operate.
7-2-1. Circuit breaker trips (or fuse blows).
7-2-2. Neither fan motor nor compressor motor runs.
A. Power is not supplied.
B. Check "MODE selector" on the control panel.
C. Check transformer.
7-3. Some part of air conditioner does not operate.
7-3-1. Only fan does not run.
7-3-2. Electric heater does not work.
7-3-3. Only compressor unit does not run.
7-4. Air conditioner operates, but abnormalities are observed.
7-4-3. Excessive cooling or heating.
7-5. If a sensor is defective. (Only for heat pump model)
7-5-1. Room temp. thermistor (RTH) is defective.
8-1. Measurement of Insulation Resistance
8-1-1. Power Cord and Unit
8-1-2. Measurement of Insulation Resistance for Electrical Parts
8. CHECKING ELECTRICAL COMPONENTS
8-2. Checking Motor Capacitor
8-3. Checking Fan Motor Winding
8-4. Checking Compressor Motor Winding
8-6. Checking Thermistor
9. DISASSEMBLY PROCEDURE
9-4. Removing Electric Heater
9-5. Removing Blower Wheel
9-6. Removing Evaporator
9-7. Removing Condenser
9-8. Removing Propeller Fan
9-9. Removing Fan Motor
10. FUNCTION
10-1. Room Temperature Control
Heating
Heating (Except during defrosting operation)
10-2. Defrosting Operation (Heating)
Control Panel
Heat Pump Model Model STB0823H1
HIGH
THERMOSTAT SELECTOR
APPENDIX
Fan Switch