Sanyo STB1023C1 Heating Capacity Heat pump Performance, Outdoor ambient temperature F DB

Models: STB1020C1 STB1220C1 STB0811C1 STB1023C1 STB0810C1 STB1010C1 STB1123C1 STB0823H1

1 52
Download 52 pages 25.9 Kb
Page 21
Image 21

5-2. Heating Capacity (Heat pump Performance)

Model STB0823H1

Fan speed : High

Heating capacity ratio (%)

NOTE

120

110

100

90

80

70

60

50

40

30

20

10

0

17

20

30

40

47

50

60

Outdoor ambient temperature (°F DB)

1) … Point of rating condition

Black dot in the chart indicates the following rating condition.

Indoor: 70°F (21.1°C) D.B.

Outdoor: 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.

2)Above characteristics indicates heat pump heating operation, which does not include elctric heater operation.

3)Because this air conditioner heats a room by drawing in the heat of the outside

air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low, which consequently makes the room temperature decrease. At this time, heat is provided by the electric heater instead of heat pump. See page 44 for detail.

17

Page 21
Image 21
Sanyo STB1023C1, STB0823H1, STB0810C1, STB1020C1 Heating Capacity Heat pump Performance, Outdoor ambient temperature F DB