Control/Address Settings
When you connect the camera to a controller, it is necessary to configure the interface board control switch and address switch.
This is used to configure transmission rate and protocol, etc.
¥Switches 2 and 3 are not used.
¥Settings in bold typeface in the table below show the factory default configurations.
❶Baud RateON
6 5 4 3 2 1
Configure the transmission rate of connected devices to the transmission | ❶ ❷ | ❸ | |||
rate of the camera. |
|
|
| ||
|
|
|
|
| |
|
|
|
|
|
|
Transmission Rate | Switch 6 | Switch 5 |
|
|
|
2400 | OFF | OFF |
|
|
|
4800 | ON | OFF |
|
|
|
9600 | OFF | ON |
|
|
|
19200 | ON | ON |
|
|
|
When protocol is set to “PELCO”, set to 2400.
❷ProtocolSelect the protocol for controlling the camera.
Protocol | Switch 4 | Corresponding Protocol |
SSP (SANYO) | OFF | Automatic switching between Sanyo SSP and high speed SSP |
PELCO | ON | Automatic switching between |
When you connect multiple cameras, set the terminator setting (Switch 1) of the final device to ÒONÓ and all other devices to ÒOFFÓ.
■Address switchIf you use the RS485 communication mode, assign a unique address (camera No.) to each camera.
Configure the address by setting the dip switches to ÒONÓ and ÒOFFÓ. | ON |
|
|
|
|
|
|
|
For further information, refer to the ÒAddress Settings TableÓ on |
|
|
|
|
|
|
|
|
the next page. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|