8. AWB Adjustment
Serial cable
Camera 0 - 18 cm
All white pattern
Color viewer(5,100K)
Preparation:
POWER switch: ONAdjusting method:
1.Set the all white pattern so that it becomes a full picture. (Do not enter any light.)
2.
9. Frange-back Adjustment
Screw driverLens | Adjustment screw |
Fig. 1
Focus switch Macro position Normal positionFig. 2
Preparation:
POWER switch: ON
Adjusting location:
Adjust the adjustment screw by turning it through the hole provided in the CA1 board. If this adjustment screw is turned
Adjustment method:
1.Display the image taken by the camera on the screen of a computer.2.Set the focus switch at the normal position.3.Project two Siemens star charts at a distance of 1.0 meters and 0.3 meters infront of the lens.
4.Turn the adjustment screw until the Siemens star which is 1.0 meters away is exactly in focus. Check that the Siemens star which is 0.3 meters from the front of the lens is out of focus at this time.
5.Project the Siemens star chart at a distance of 0.3 meters in front of lens. Check that it is out of focus at normal mode, and it is in focus at macro mode.
6.This adjustment location is integrated with the iris mecha- nism. After adjusting, make sure that no load has been placed on the iris mechanism and harness.
10. LCD Panel Adjustment
[CA1 board (Side B)]
CL426CL424 CL42510-1. LCD H AFC Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1.3.While watching the LCD monitor, adjust “H AFC” so that the edge of the LCD adjustment frame are the same distance from the left and right edge of the LCD screen. (A = B)