21
ESC+IP0
Command ESC IP0 Parameter
Hex code <1B>16 <49>16<50>16<30>16 e, d, k, a, u, m, f,p, s, t, c, n
Initial value Nil
When power switch is
OFF
The set command is not maintain ed.
Valid range within item The set parameter becomes invalid.
Valid range
and term of
command Valid range between
items
The set parameter becomes invalid.
[Function]
This is a control function for Writing dat a to Gen2 RFID tag.
[Format]
<IP0> e: x , d:xxxxxxxxxxxxxxxxxxxxxxxx, k:xxxxxxxx, a:xxxxxxxx, p:xxxxxxxx , u:x….x, m:xxxxx,f:x, p:xx,
s:xx, c: xx, t:x, n:xxxxxxxxxxxx;
[Parameters]
e = [EPC Type]
a: EAN128 SSCC 96
c: EAN13 SGTIN 96
z: free mapping
d = [EPC Data] 24 digits if ‘e’ = z
17 digits if ‘e’ = a
13 digits if ‘e’ = c
Parameters when ‘e’ = Free mapping
k = [Kill code] (Max. Data Length is 8 bytes, Data should be Hex (0 to F))
a = [Present Access Code] (Max. Data Length is 8 bytes, Data should be Hex (0 to F))
p = [New Access Code] (Max. Data Length is 8 bytes Data should be Hex (0 to F))
u = [User Memory] (Max. Data Length depends o n the tag manufacturer, Data should be Hex
(0 to F))
m = [Locking of blocks] (5 digit Mask, 0: Unlock 1: Lock)
Block Mask byte (digit
from right)
EPC Area (d) 00001 (0)
Kill Code (k) 00010 (1)
Access code (a) 00100 (2)
TID Area 01000 (3)
User Memory (u) 10000 (4)
When e = “a” (EAN128 SSCC 96) or “c”(EAN13 SGT IN 96)
f = filter value (a value between 0 and 7)
s = total number of digits for serial reference (Should be any value with 5 to 11, a combinat ion
of s and c should be 17. Applica ble only if
EAN128 SSCC 96 is selected)
t = total number of digits for item refer ence (Should be any valu e with 1 to 7, a combination
of s and c should be 13. Applicable only if