10
I
ntro
d
uct
i
on to t
h
e
RFID
con
fi
gurat
i
on opt
i
ons
Tag Write Cnt
Displays the number of tags attem pted to be written since the last Clear Tag Stat operat ion was initiated.
(See “Clear Tag Stat”.)
Failed Tag Cnt
Displays on the LCD the numbe r of failed tag write attempts since the last Clear T ag Stat operation has
been initiated. (See “Clear Tag Stat”)
Tag Read Cnt
This menu item displays the number of tags r ead since the last Clear Tag Stat. (See “Clear Tag Stat”)
Non-RFID Warning
When set to Enable, this option causes the p rinter to check to make sure that non-RFID jobs are not
being printed on RFID labels (to prevent RFID labels from being wasted).
If RFID labels are installed in the printe r, and a job is printed with at least one form that co ntains no RFID
commands, a fault will be declared and the data f or the forms that contain no RFID commands will be
absorbed.
The default is Disable.
Tag Void Cnt
Always displays 0 unless the RFID enco der is used with an attached Online Barcode Validator (OBV).
When used with a validator, T ag Void Cnt represents how many valid RFID tags were overstruck due to
bad barcode scanning.