CT4xx Series Quick Guide | Pg 2 |
What You Get
The CT Series Thermal Transfer printer comes packed in a protective carton. Included in the carton are the following items :
•CT400 / CT410 Printer
•Quick Guide
•Driver / Manual CD ROM
•Power Module AC Power Cord
•Cleaning Solution & Cloth (Not for Export out of Singapore)
CT4xx Series Quick Guide | Pg 11 |
6.If you are still unable to get printer output, try the Hex Dump as described in Step 5 under the Parallel Interface troubleshooting. In this case, the printer monitors its RS232C interface for incoming data.
7.From the Hex Dump, if you are seeing no extra 0D 0A (CR & LF) characters, and are using BASIC, refer to the beginning of the Command Code section. It provides hints for writing a SATO program in BASIC.
Error Signals
The
Dis- | LED Indicators | Buzzer | Error | Corrective | ||
play | LINE | ERROR | Condition | Action | ||
| ||||||
0 |
| ON | 1 Beep | Flash Memory | Replace Flash ROM | |
| error | |||||
|
|
|
|
| ||
1 |
|
|
| Not Assigned |
| |
2 |
| ON | 1 Beep | Motherboard error | Replace PCB | |
3 |
| ON | 1Beep | EEPROM error | Replace EEPROM | |
4 |
| ON | 1 Beep | Electrical Head | Replace Print Head | |
5 |
| Blink | 3 Beeps | Head not latched | Latch Print Head | |
6 |
| Blink | 3 Beeps | Out of Paper | 1) Replenish paper | |
| 2) Route Paper thru sensor | |||||
|
|
|
|
| ||
7 |
| Blink | 3 Beeps | Sensor error | 1) Select correct sensor | |
| 2) Adjust sensor level | |||||
|
|
|
|
| ||
8 |
| Blink | 3 Beeps | Cutter error | Connect cutter | |
8. | ON | ON |
| Program | Retry download | |
| download error | |||||
|
|
|
|
| ||
9 |
| Blink | 3 Beeps | Ribbon End (TT | Replace ribbon | |
| mode only) | |||||
|
|
|
|
| ||
A | ON |
| 1 Beep | Receive buffer | 1) Modify host SW | |
| overflow | 2) Select correct protocol | ||||
|
|
|
| |||
b | ON |
| 1 Beep | Parity error | Correct Parity Settings | |
| (Serial I/F only) | |||||
|
|
|
|
| ||
c | ON |
| 1 Beep | Framing error | Correct data bit setting | |
| (Serial I/F only) | |||||
|
|
|
|
| ||
d | ON |
| 1 Beep | Overrun error | Correct flow control | |
| (Serial I/F only) | settings | ||||
|
|
|
| |||
E | ON |
| 1 Beep | LAN Time Out | Replace LAN I/F | |
| Error | |||||
|
|
|
|
| ||
F |
|
| 3 Beeps | Download Font / | Correct data stream | |
|
| Graphic Error | ||||
|
|
|
|
|