Enabling the Error-Disabled Recovery

Configuring Ethernet Interfaces

Enabling the Error-Disabled Recovery

Enabling the Error-Disabled Recovery

You can specify the application to bring the interface out of the error-disabled (err-disabled) state and retry coming up. It retries after 300 seconds, unless you configure the recovery timer (see the errdisable recovery interval command).

Procedure

 

Command or Action

Purpose

Step 1

config t

Enters configuration mode.

 

Example:

 

 

switch#config t

 

 

switch(config)#

 

Step 2 errdisable recovery cause {all udld bpduguard link-flap failed-port-state pause-rate-limit}

Example:

switch(config)#errdisable recovery cause all

switch(config-if)#

Specifies a condition under which the interface automatically recovers from the err-disabled state, and the device retries bringing the interface up. The device waits 300 seconds to retry. The default is disabled.

Step 3

show interface status err-disabled

Displays information about err-disabled

 

 

interfaces.

 

Example:

 

 

switch(config)#show interface status

 

 

err-disabled

 

Step 4

copy running-config startup-config

(Optional) Copies the running configuration to

 

 

the startup configuration.

 

Example:

 

 

switch(config)#copy running-config

 

 

startup-config

 

This example shows how to enable err-disabled recovery under all conditions:

switch(config)#errdisable recovery cause all switch(config)#

Configuring the Error-Disabled Recovery Interval

You can use this procedure to configure the err-disabled recovery timer value. The range is from 30 to 65535 seconds. The default is 300 seconds.

Cisco Nexus 3000 NX-OS Layer 2 Switching Configuration Guide, Release 5.0(3)U3(1)

OL-26590-01

19