Cisco Systems N3KC3064TFAL3, N3KC3048TP1GE manual Displaying Input Packet Discard Information

Models: N3KC3064TFAL3 N3KC3048TP1GE

1 164
Download 164 pages 5.98 Kb
Page 37
Image 37
Displaying Input Packet Discard Information

Configuring Ethernet Interfaces

Displaying Input Packet Discard Information

Trunk encap. type:

802.1Q

Channel:

yes

Broadcast suppression:

percentage(0-100)

Flowcontrol:

rx-(off/on),tx-(off/on)

Rate mode:

none

QOS scheduling:

rx-(6q1t),tx-(1p6q0t)

CoS rewrite:

no

ToS rewrite:

no

SPAN:

yes

UDLD:

yes

MDIX:

no

FEX Fabric:

yes

The following example shows how to display the physical Ethernet transceiver:

switch# show interface ethernet 1/1 transceiver Ethernet1/1

sfp is present

name is CISCO-EXCELIGHT part number is SPP5101SR-C1 revision is A

serial number is ECL120901AV nominal bitrate is 10300 MBits/sec

Link length supported for 50/125mm fiber is 82 m(s) Link length supported for 62.5/125mm fiber is 26 m(s) cisco id is --

cisco extended id number is 4

The following example shows how to display a brief interface status (some of the output has been removed for brevity):

switch# show interface brief

--------------------------------------------------------------------------------

Ethernet

VLAN

Type Mode Status Reason

Speed

Port

Interface

 

 

 

Ch #

--------------------------------------------------------------------------------

Eth1/1

200

eth

trunk

up

none

10G(D) --

Eth1/2

1

eth

trunk

up

none

10G(D) --

Eth1/3

300

eth

access

down

SFP not inserted

10G(D) --

Eth1/4

300

eth

access

down

SFP not inserted

10G(D) --

Eth1/5

300

eth

access

down

Link not connected

1000(D) --

Eth1/6

20

eth

access

down

Link not connected

10G(D) --

Eth1/7

300

eth

access down

SFP not inserted

10G(D) --

...

 

 

 

 

 

 

The following example shows how to display the CDP neighbors:

switch# show cdp neighbors

Trans-Bridge, B -

Source-Route-Bridge

Capability Codes: R

- Router, T -

S

-

Switch, H -

Host, I - IGMP, r

- Repeater,

V

-

VoIP-Phone,

D - Remotely-Managed-Device,

Device ID

s - Supports-STP-Dispute

Capability

Platform

Port ID

Local Intrfce

Hldtme

d13-dist-1

mgmt0

148

S I

WS-C2960-24TC Fas0/9

n5k(FLC12080012)

Eth1/5

8

S I s

N5K-C5020P-BA

Eth1/5

Displaying Input Packet Discard Information

Beginning with Cisco NX-OS Release 5.0(3)U2(1), you can get detailed information on what specific condition led to an input discard on a given interface. Use the show hardware internal interface indiscard-statsfront-portx command to determine the condition that could be potentially responsible for the input discards that are seen on port eth1/x. The switch output shows the discards for IPv4, STP, input policy, ACL specific discard, generic receive drop, and VLAN related discards.

This example shows how to determine the condition that could be potentially responsible for the input discards:

switch# show hardware internal interface indiscard-stats front-port 1

Cisco Nexus 3000 NX-OS Layer 2 Switching Configuration Guide, Release 5.0(3)U3(1)

OL-26590-01

23

Page 37
Image 37
Cisco Systems N3KC3064TFAL3, N3KC3048TP1GE manual Displaying Input Packet Discard Information