Schumacher 1020. SEC-1, WS-63, SE-82-6, CM-1, MC-1, 83, 86, 84 Page, L Output Current Selector Switch

Models: 1020 212

1 6
Download 6 pages 59.14 Kb
Page 5
Image 5
L OUTPUT CURRENT SELECTOR SWITCH

L OUTPUT CURRENT SELECTOR SWITCH

In addition to the voltage selector switch, some models are equipped with a two position switch, allowing the operator to select the ampere charge rate to a battery, as follows:

MODELS

 

WS or SE- or SEC-

SWITCHSETTING

 

 

82-6

6 or 2 Amps (Trickle)

1010-2

10 or 2 Amps (Trickle)

1015

15 or 3 Amps (Trickle)

1020

20 or 3 Amps (Trickle)

-

Before making any connections to battery, read instructions F, G and H carefulIy.

Connect DC output clips only when AC power supply cord is removed from electrical outlet.

Never allow cilps to touch each other.

M.CHARGE PERIOD: The approximate required time to bring a battery to full charge state depends upon the number of ampere hours (AH) depleted from the battery. AH’s are determined by multiplying the number of hours times the number of Amps supplied by a battery to a load.

For example - If a load was connected to a battery, which drew 7 Amps for a period of 5 hours, the battery will have supplied 35 AH. The approximate recharge time would then be calculated by dividing the 35 AH depleted from the battery, by the ampere charge rate of the charger. To allow for tapering of the charge rate add 25 percent to the charge time.

Indications of a fully charged battery are:

When the ammeter indicates the charge rate has tapered to approximately one half the charger rated output.

A hydrometer reading of the specific gravity of the electrolyte (fluid) of a battery in good condition should be between 1.250 and 1.285.

When a battery reaches 80 - 85% of full charge bubbles will appear on the surface of the fluid. As the battery nears full charge, bubbling will become more noticeably vigourous.

Disconnecting from Battery:

Before disconnecting from battery read instructions F. G and H carefully.

N.STORAGE: Store battery charger In a dry area.

O.PROBLEMCHECKLIST

1.If no meter reading, check the following:

a.Remove the charger power cord plug from the AC outlet and recheck the battery charger clips for clean, tight connections.

b.Check voltage selector switch for proper setting.

c.Check for voltage at the AC outlet by plugging in a lamp or other appliance.

2.If Ammeter pointer moves to extreme right, remains a short time, then returns to zero, accompanied by a cilcking sound, check the following:

a.Possibly, the charger connections are reversed. (Positive to negative, instead of positive to positive).

Page 5