Troubleshooting

Problem

Check

Solution

 

 

 

No display/partial diplay/unit will not turn

Check electrical (wall) outlet

Make sure unit is plugged into a

on

 

functioning wall outlet.

 

 

 

 

Check connection at front (recumbent) or

Connection should be secure and

 

rear (upright) of unit

undamaged. Replace adapter or

 

 

connection at unit if either are damaged.

 

 

 

 

Check data cable integrity

All wires in cable should be intact. If any

 

 

are visibly crimped or cut, replace cable.

 

 

 

 

Check data cable

Insure cable is connected securely

 

connections/orientation

and oriented properly. Small latch on

 

 

connector should line up and snap into

 

 

place.

 

 

 

 

Check console display for damage

Check for visual sign that console display

 

 

is cracked or otherwise damaged.

 

 

Replace Console if damaged.

 

 

 

 

Console Display

If Console only has partial display and

 

 

all connections are fine, replace the

 

 

Console.

 

 

 

 

 

If the above steps do not resolve the

 

 

problem, contact Customer Care for

 

 

further assistance.

 

 

 

Unit operates but Contact HR not

HR cable connection at Console

Insure cable is connected securely to

displayed

 

Console.

 

 

 

 

HR cable box connection (recumbent

Insure cables from handlebars and cable

 

only)

to Console are secure and undamaged.

 

 

Some models may require the seat back

 

 

be raised to access cable box.

 

 

 

 

Sensor grip

Insure hands are centered on HR

 

 

sensors. Hands must be kept still with

 

 

relatively equal pressure applied to each

 

 

side.

 

 

 

 

Dry or calloused hands

Sensors may have difficulty with dried

 

 

out or calloused hands. A conductive

 

 

electrode cream such as "Signa Crème"

 

 

or "Buh-Bump" can help make better

 

 

conduct. These are available on the

 

 

web or at medical or some larger fitness

 

 

stores.

 

 

 

 

Handlebars

If tests reveal no other issues, Handlebars

 

 

should be replaced.

Unit operates but Telemetric (if equipped) Chest Strap HR not displayed

Strap should be "Polar" compatible. Make sure strap is directly against skin and contact area is moist.

Interference

Try moving unit away from sources of

 

interference (TV, Microwave, etc). If

 

interference is eliminated and HR still

 

does not function, replace strap and

 

Console.

 

 