SCCG30 & SCCP30

Service Manual

Performance Information

Listed cycle times are after the 3rd consecutive cycle, will vary a minute or so, and will be longer for built in units.

Freeze Cycle, Minutes

 

 

 

Air Temperature

 

 

100

90

80

 

70

60

50

 

 

 

 

100

60

46

45

 

43

42

40

 

90

54

44

42

 

40

38

36

 

80

45

40

38

 

37

35

34

Water

70

40

37

35

 

33

32

30

Temperature

 

60

31

30

27

 

26

24

23

 

 

 

50

24

23

22

 

21

20

19

 

40

23

21

20

 

19

18

18

Harvest time is usually 2 minutes, longer in very cold conditions.

Total Cycle, Minutes

 

 

 

Air Temperature

 

 

100

90

80

 

70

60

50

 

 

 

 

100

62

48

47

 

45

44

42

 

90

56

46

43

 

42

40

38

 

80

47

42

39

 

39

37

36

Water

70

42

39

37

 

35

33

32

Temperature

 

60

32

32

29

 

26

26

23

 

 

 

50

26

25

23

 

23

22

24

 

40

25

22

22

 

21

24

23

Ice per cycle: 1/2 lb

Water drained / cycle: Varies by harvest cycle length and purge setting. Typically about 3 pints.

Compressor amps: 2.9 - 3.1