SCCG30 & SCCP30
Service Manual
Performance Information
Listed cycle times are after the 3rd consecutive cycle, will vary a minute or so, and will be longer for built in units.
Freeze Cycle, Minutes |
|
|
| Air Temperature |
|
| ||
100 | 90 | 80 |
| 70 | 60 | 50 | ||
|
|
| ||||||
| 100 | 60 | 46 | 45 |
| 43 | 42 | 40 |
| 90 | 54 | 44 | 42 |
| 40 | 38 | 36 |
| 80 | 45 | 40 | 38 |
| 37 | 35 | 34 |
Water | 70 | 40 | 37 | 35 |
| 33 | 32 | 30 |
Temperature |
| |||||||
60 | 31 | 30 | 27 |
| 26 | 24 | 23 | |
|
| |||||||
| 50 | 24 | 23 | 22 |
| 21 | 20 | 19 |
| 40 | 23 | 21 | 20 |
| 19 | 18 | 18 |
Harvest time is usually 2 minutes, longer in very cold conditions.
Total Cycle, Minutes |
|
|
| Air Temperature |
|
| ||
100 | 90 | 80 |
| 70 | 60 | 50 | ||
|
|
| ||||||
| 100 | 62 | 48 | 47 |
| 45 | 44 | 42 |
| 90 | 56 | 46 | 43 |
| 42 | 40 | 38 |
| 80 | 47 | 42 | 39 |
| 39 | 37 | 36 |
Water | 70 | 42 | 39 | 37 |
| 35 | 33 | 32 |
Temperature |
| |||||||
60 | 32 | 32 | 29 |
| 26 | 26 | 23 | |
|
| |||||||
| 50 | 26 | 25 | 23 |
| 23 | 22 | 24 |
| 40 | 25 | 22 | 22 |
| 21 | 24 | 23 |
Ice per cycle: 1/2 lb
Water drained / cycle: Varies by harvest cycle length and purge setting. Typically about 3 pints.
Compressor amps: 2.9 - 3.1
September 2009