| SCCG30 & SCCP30 | |
|
| Service Manual | |
Service Diagnosis |
|
| |
Makes excessive noise |
|
| |
|
|
| |
Problem | Likely Cause | Probable Solution | |
Fan blade vibrates | Blade is bent | Replace fan blade | |
Fan motor mount is broken | Replace motor mount | ||
| |||
Compressor vibrates | Mounting loose | Check mounting | |
Water pump vibrates | Pump bearings worn | Replace pump | |
Panels vibrate | Mounting screws loose | Tighten screws |
Makes ice, does not harvest
Problem
Likely Cause
Probable Solution
Ice wrong size | Environment changed | Adjust cube size |
|
| Check voltage to coil when unit is |
Little heat to evaporator | Hot gas valve does not open | in harvest, check controller |
| indicator light. | |
|
| |
| Water temperature very low | Adjust harvest time |
Makes poor quality ice
Problem
Likely Cause
Probable Solution
Spray pattern poor | Spray jets dirty | Clean jets |
Runs out of water | Water leaking from reservoir | Correct leak |
High TDS water supply | Groundwater supply | Treat water |
Makes ice, but melts rapidly
Problem
Likely Cause
Probable Solution
Restricted drain, water in bin
Gravity drain hose has air block | Check for kinks or traps | |
Pump model switch not starting | Check / replace switch | |
pump | ||
|
September 2009