BG 2000 Specifications and Operating Characteristics
|
|
|
|
|
|
Horsepower | 1 HP | 1HP |
Refrigerant | ||
Oil | Polyol ester oil | Polyol ester oil |
Locked rotor amps | 76.7 | 45 |
Current draw with pump | 26.8 amps | 14.10 amps |
Electrical breaker | 30 amp | 15 amp double |
|
| pole |
Maximum refrigerant charge | 24 oz | 24 oz |
Manual reset high pressure | 325 PSIG | 325 PSIG |
March pump | ||
Integral low voltage thermostat circuit |
Pressure trends: Gauge pressure PSIG
|
|
|
| Water temp 60 | Water temp 80 |
| degrees F. | degrees F. |
Hi Pressure | 175 | 190 |
Low Pressure (Warm Plates) | 30 | 30 |
Low pressure (Cold Plates) | 7 to 5 | 7 to 5 |
|
|
|
Pressures are approximate: High pressure will momentarily rise beyond operating pressure until the expansion valve starts to restrict flow. Condensing pressure will be 15 degrees above water temp.
Low pressure will drop from equalized at start up to settle at the indicated low reading in a period of about 45 minutes depending on the number of plates and starting temperature. Proper thermostat set up should cycle the compressor in this low- pressure range.
THE EXPANSION VALVES HAVE BEEN FACTORY ADJUSTED FOR OPTIMUM PERFORMANCE. DO NOT ADJUST THIS VALVE FOR ANY REASON. INCORRECT SETTINGS MAY RUIN THE COMPRESSOR!
30