Sea Frost BG 2000 installation instructions volt50/60 hz, Pressure trends Gauge pressure PSIG

Models: BG 2000

1 37
Download 37 pages 59.01 Kb
Page 30
Image 30
115-volt 50/60 hz

BG 2000 Specifications and Operating Characteristics

 

 

 

 

115-volt 50/60 hz

230-volt 50/60 hz

Horsepower

1 HP

1HP

Refrigerant

404-a

404-a

Oil

Polyol ester oil

Polyol ester oil

Locked rotor amps

76.7

45

Current draw with pump

26.8 amps

14.10 amps

Electrical breaker

30 amp

15 amp double

 

 

pole

Maximum refrigerant charge

24 oz

24 oz

Manual reset high pressure cut-out

325 PSIG

325 PSIG

March pump

LC-3

LC-3

Integral low voltage thermostat circuit

24-volt AC

24-volt AC

Pressure trends: Gauge pressure PSIG

 

 

 

 

Water temp 60

Water temp 80

 

degrees F.

degrees F.

Hi Pressure

175

190

Low Pressure (Warm Plates)

30

30

Low pressure (Cold Plates)

7 to 5

7 to 5

 

 

 

Pressures are approximate: High pressure will momentarily rise beyond operating pressure until the expansion valve starts to restrict flow. Condensing pressure will be 15 degrees above water temp.

Low pressure will drop from equalized at start up to settle at the indicated low reading in a period of about 45 minutes depending on the number of plates and starting temperature. Proper thermostat set up should cycle the compressor in this low- pressure range.

THE EXPANSION VALVES HAVE BEEN FACTORY ADJUSTED FOR OPTIMUM PERFORMANCE. DO NOT ADJUST THIS VALVE FOR ANY REASON. INCORRECT SETTINGS MAY RUIN THE COMPRESSOR!