It is IMPORTANT that NO WATER flows between the plastic housing and the pump body. The screws that hold the cover also seal the housing. Water behind the housing will ruin the motor bearings.

BE SURE THE PUMP HOUSING IS ABSOLUTELY DRY BEFORE DISASSEMBLY.

Remove the phillips screws holding the inlet fitting plate (larger hose size). The impeller may then be removed along with it’s ceramic seal and thrust washer. Reassemble in the reverse order. (An exploded diagram is in this manual.) Observe the "O" ring that seals the housing cover plate. Make sure it is in good condition. Open the seacock. Inspect for leaks.

NEVER OPERATE THE PUMP WHILE DRY. IF IT IS SUSPECTED THAT THIS CONDITION HAS OCCURRED, INSPECT THE IMPELLER AND HOUSING FOR WEAR.

CHECKING THE REFRIGERANT CHARGE

SIGHT GLASS LOCATION

The BG 2000 system is fitted with a sight glass located in the top of the RECEIVER/FILTER/DRIER (RFD). (The RFD is a round blue canister about 9 inches high and 3 inches in diameter. It is located in the left corner of the compressor housing.)

The charge level should be inspected to be sure refrigerant is of the proper amount and that there are no slow leaks. Switch the unit on and immediately inspect the sight glass. White foam with high velocity should be observed and after a minute or two show a black or clear condition. A clear glass and an empty glass will look the same. A transition must be seen to be sure that refrigerant is present. Do not operate a low or empty system. See; "Leak Checking” and “Adding Charge". (Page 22)

LAY-UP (Winterizing)

Flush the pump and condenser with plenty of fresh water. Pressure water should be flushed through the inlet side of the water pump. In freezing climates antifreeze should be pumped through, after flushing, by operating the system for a very brief period. Connect a short hose to the suction side of the pump to draw from a bucket. Run the pump (switch on unit) until antifreeze is discharged. (The pump is not self-priming and may require filling the hose and pump with a funnel). DO NOT RUN THE PUMP DRY. It is water lubricated.

7

Page 7
Image 7
Sea Frost BG 2000 installation instructions LAY-UP Winterizing

BG 2000 specifications

The Sea Frost BG 2000 is a premier refrigeration unit designed to meet the demanding requirements of marine vessels. This advanced cooling system is engineered to provide reliable refrigeration performance even under the most challenging seawater conditions, making it a popular choice among boat owners and commercial fishermen.

One of the main features of the Sea Frost BG 2000 is its innovative evaporator design. The unit employs a unique coil configuration that maximizes surface area for heat exchange, enhancing efficiency and cooling performance. This design ensures that your onboard refrigeration maintains optimal temperatures while consuming less power. This efficiency is crucial for extending the lifespan of gathered produce and maintaining the quality of stored goods.

The BG 2000 utilizes cutting-edge compressor technology, enabling it to deliver superior cooling capacity while minimizing noise and vibration. Its compressor is hermetically sealed, reducing the risk of leakage and ensuring a long operational lifespan. Additionally, the compressor’s variable speed operation allows for tailored cooling performance, adapting to the varying demands of the refrigeration system.

The Sea Frost BG 2000 is engineered for flexibility and ease of installation. Its compact design allows for simple integration into various types of vessels without significant modifications. Furthermore, the unit comes with a user-friendly control panel, giving users the ability to monitor temperatures and adjust settings effortlessly. This ensures that boat owners can maintain optimal refrigeration conditions without the hassle of complicated setups.

Another notable characteristic of the BG 2000 is its robust build. The unit is constructed with corrosion-resistant materials, ensuring durability in the harsh marine environment. This durability extends to its components, which are designed to withstand the rigors of saltwater exposure, ensuring a long service life under demanding conditions.

To further improve its functionality, the Sea Frost BG 2000 incorporates environmentally-friendly refrigerants that comply with modern regulations, promoting sustainability without compromising performance. With an emphasis on energy efficiency, this unit helps reduce fuel consumption, which is a critical consideration for marine operations seeking to lower operational costs.

In summary, the Sea Frost BG 2000 stands out in the marine refrigeration market, boasting advanced features, durable construction, and efficient operation. Its innovative design and technology make it an invaluable asset for any vessel looking to maintain high-quality refrigeration in an eco-friendly manner. Whether for commercial fishing or leisure cruising, the BG 2000 proves to be a reliable and efficient choice for marine refrigeration needs.