Marathon 810 (ST9816AG) Product Manual, August 1995 | 9 | |
|
|
|
1.7.2Power recovery
Except during execution of a write command, the drive’s power can be interrupted without adversely affecting the drive or previously written data. If power is removed while the drive is performing a write operation, the integrity of the data being written cannot be guaranteed.
1.7.3Conducted noise
The drive is expected to operate with a maximum of:
∙150 mV
∙100 mV
Note. Equivalent resistance (11.9 ohms) is calculated by dividing the nominal voltage (5.0V) by the typical RMS read/write current (0.420 amps).
1.7.4Voltage tolerance
Voltage tolerance (including noise): +5 volts + 5% – 10%
1.7.5Power-management modes
Power management is required for
Active mode. The drive is in Active mode during the read/write and seek operations.
Idle mode. At
Standby mode. The drive enters Standby mode when the host sends a Standby Immediate command. If the standby timer has been set by the host system, the drive can also enter Standby mode automatically after the drive has been inactive for a specifiable length of time. The standby timer delay