Table 1: Fluid Dynamic Bearing (FDB) motor acoustics
| Acoustic mode |
|
|
|
|
Models | Idle* | Quiet seek |
|
|
|
ST3160022A | <2.5 bels (typ) | 2.8 bels (typ) |
ST3120025A | 2.7 bels (max) | 3.0 bels (max) |
ST380012A |
|
|
ST360019A |
|
|
|
|
|
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
2.12Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
|
| Performance | Reference |
Test | Description | level | standard |
|
|
|
|
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: | B | EN |
| ± 8 kV |
|
|
|
|
|
|
Radiated RF immunity | 80 to 1,000 MHz, 3 V/m, | A | EN |
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
| 900 MHz, 3 V/m, 50% pulse |
|
|
| modulation @ 200 Hz |
|
|
|
|
|
|
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on | B | EN |
| external I/O |
|
|
|
|
|
|
Surge immunity | ± 1 kV differential, ± 2 kV com- | B | EN |
| mon, AC mains |
|
|
|
|
|
|
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, | A | EN |
| 80% AM with 1 kHz sine |
|
|
|
|
|
|
Voltage dips,interrupts | 0% open, 5 seconds | C | EN |
| 0% short, 5 seconds | C |
|
| 40%, 0.10 seconds | C |
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
2.13 | Reliability |
|
|
| |
Nonrecoverable read errors | 1 per 1014 bits read, max. | |
Mean time between failures | 600,000 | |
|
| |
Contact | 50,000 cycles | |
|
| (at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle) |
|
| |
Service Life | 5 Years | |
|
| |
Preventive maintenance | None required | |
|
|
|
12 | U Series 9 Product Manual, Rev. D |