Cheetah 15K.5 FC Product Manual, Rev. F
43
8.0 Installation
Cheetah 15K.5 FC disc drive installation is a plug-and-play process. There are no jumpers, switches, or termi-
nators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC-
SCA)no cables are required. See Section 9.5 for additional information about this connector.
Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.
If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL
IDs) on the backpanel so that no two devices have the sam e select ion ID . This is ca lle d the hard assi gn ed ar bi-
trated loop physical address (AL_PA). There are 1 25 A L_PAs available (see T a ble 26) . If you set th e AL_PA on
the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this
AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec-
tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set
the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto-
matically.
Loop initialization is the process used to verify or obtain an address. The loop initialization process is per-
formed when power is applied to the drive, when a device is added or re moved from the F ib re Cha nnel l oop , or
when a device times out attempting to win arbitration.
Set all option selections in the connector prior to applying power to the drive. If you change options after
applying power to the drive, recycle the drive power to activate the new settings.
It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in
512-byte logical blocks. You need to refo rma t the drive only if you want to se lect a dif fer ent lo gical blo ck size.

8.1 Drive ID/option selection

All drive options are made through the interface connector (J1). Table 23 provides the pin descriptions for the
40-pin Fibre Channel single connector (J1).

8.2 Drive orientation

The drive may be mounted in any orientation. All drive performance characterizations, however, have been
done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two pre-
ferred mounting orientations.

8.3 Cooling

The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed
to ensure that the drive operates within the temperature m easur emen t guide lines descr i bed in Secti o n 6.4.1. In
some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in
Section 6.4.1.