Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location.
• Standby mode
During Standby mode, the drive accepts commands, but the drive is not spinning, and the servo and read/ write electronics are in
Table 3: DC power requirements
Power dissipation using consumer |
|
|
|
storage profile (ST3750840ACE values | Average | Average | Average |
shown) | (watts, 25° C) | 5V typ amps | 12V typ amps |
|
|
|
|
Spinup | — | — | 2.0 (peak) |
|
|
|
|
Idle* | 9.30 | 0.611 | 0.540 |
|
|
|
|
Idle with offline activity | 10.40 | 0.719 | 0.567 |
|
|
|
|
Operating (CE seeks) | 8.20 | 0.425 | 0.510 |
|
|
|
|
Standby | 0.80 | 0.106 | 0.023 |
|
|
|
|
Sleep | 0.80 | 0.106 | 0.023 |
|
|
|
|
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
DB35.3 Series PATA Product Manual, Rev. B | 11 |