2.11Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5: | Radio frequency environments |
|
| |
|
|
|
|
|
|
|
| Performance | Reference |
Test |
| Description | level | standard |
|
|
|
| |
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: | B | EN | |
|
| ± 8 kV |
|
|
|
|
|
| |
Radiated RF immunity | 80 to 1,000 MHz, 3 V/m, | A | EN | |
|
| 80% AM with 1 kHz sine |
| ENV 50204: 95 |
|
| 900 MHz, 3 V/m, 50% pulse |
|
|
|
| modulation @ 200 Hz |
|
|
|
|
|
| |
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on | B | EN | |
|
| external I/O |
|
|
|
|
|
| |
Surge immunity | ± 1 kV differential, ± 2 kV com- | B | EN | |
|
| mon, AC mains |
|
|
|
|
|
| |
Conducted RF immunity | 150 kHz to 80 MHz, 3 Vrms, | A | EN | |
|
| 80% AM with 1 kHz sine |
|
|
|
|
|
| |
Voltage dips, interrupts | 0% open, 5 seconds | C | EN | |
|
| 0% short, 5 seconds | C |
|
|
| 40%, 0.10 seconds | C |
|
|
| 70%, 0.01 seconds | B |
|
|
|
|
|
|
2.12 | Reliability |
|
|
| |
Nonrecoverable read errors | 1 per 1014 bits read, max. | |
Annualized Failure Rate (AFR) | 0.68% (nominal power, 25°C ambient temperature) | |
|
| |
Contact | 50,000 cycles | |
|
| (at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle) |
|
|
|
Warranty |
| 5 years on distribution units. |
|
| To determine the warranty for a specific drive, use a web browser to access the fol- |
|
| lowing web page: |
|
| www.seagate.com/support/service/ |
|
| From this page, click on the “Verify Your Warranty” link. You will be asked to provide |
|
| the drive serial number, model number (or part number) and country of purchase. |
|
| The system will display the warranty information for your drive. |
|
| |
Preventive maintenance | None required. | |
|
|
|
2.13Agency certification
2.13.1Safety certification
The drives are recognized in accordance with UL 1950 and CSA C22.2 (950) and meet all applicable sections of IEC950 and EN 60950 as tested by TUV North America.
DB35.3 Series PATA Product Manual, Rev. B | 17 |