Table 2: | Drive specifications summary for 320, 300, and 250 Gbyte models |
| |||
|
|
|
|
| |
Drive specification | ST3320820ACE |
| ST3300820ACE | ST3250820ACE | |
|
|
|
|
| |
Formatted Gbytes (512 bytes/sector)* | 320 |
| 300 | 250 | |
|
|
|
|
| |
Guaranteed sectors | 625,142,448 |
| 586,072,368 | 488,397,168 | |
|
|
|
|
| |
Bytes per sector | 512 |
|
|
| |
|
|
|
|
| |
Default sectors per track | 63 |
|
|
| |
|
|
|
|
| |
Default read/write heads | 16 |
|
|
| |
|
|
|
|
| |
Default cylinders | 16,383 |
|
|
| |
|
|
|
|
| |
Recording density, max | 781 kbits/in |
|
| 813 kbits/in | |
|
|
|
|
| |
Track density, max | 145 ktracks/in |
|
|
| |
|
|
|
|
| |
Areal density, max | 114.4 Gbits/in2 |
|
|
| |
Spindle speed | 7,200 RPM |
|
|
| |
|
|
|
|
| |
Internal data transfer rate, max | 1,030 Mbits/sec |
|
|
| |
|
|
|
|
| |
Sustained data transfer rate, max | 72 Mbytes/sec |
|
|
| |
|
|
|
|
| |
I/O | 100 Mbytes/sec |
|
|
| |
|
|
|
|
| |
ATA | PIO modes |
|
|
| |
|
| Multiword DMA modes |
| ||
|
| Ultra DMA modes |
| ||
|
|
|
|
|
|
Cache buffer |
| 8 Mbytes |
|
|
|
|
|
|
| ||
Height, max |
| 26.1 mm (1.028 inches) |
| ||
|
|
|
| ||
Width, max |
| 101.6 mm (4.000 inches) +/- 0.010 inches |
| ||
|
|
|
| ||
Length, max |
| 146.99 mm (5.787 inches) |
| ||
|
|
|
|
| |
Weight, typical | 580 grams |
|
|
| |
|
|
|
|
| |
Average latency | 4.16 msec |
|
|
| |
|
|
|
|
| |
16 sec |
|
|
| ||
|
|
|
|
| |
Standby to ready, max | 16 sec |
|
|
| |
|
|
|
| ||
<0.8 msec (read), | <1.0 msec (write) |
| |||
|
|
|
|
| |
Average seek, read, typical | <11.0 msec |
|
|
| |
|
|
|
|
| |
Average seek, write, typical | <12.0 msec |
|
|
| |
|
|
|
|
| |
Startup current (typical) 12V (peak) | 2.0 amps |
|
|
| |
|
|
|
|
| |
Voltage tolerance (including noise) | 5V ± 5% |
|
|
| |
|
| 12V ± 10% |
|
|
|
|
|
|
|
| |
Ambient temperature |
|
|
|
| |
operating |
| 0° to 65°C |
|
|
|
nonoperating |
|
|
| ||
|
|
| |||
Temperature gradient, max | 20°C per hour (operating) |
| |||
|
| 30°C per hour (nonoperating) |
| ||
|
|
| |||
Relative humidity | 5% to 90% (operating) |
| |||
|
| 5% to 95% (nonoperating) |
| ||
|
|
|
|
| |
Relative humidity gradient, per hour max | 30% |
|
|
| |
|
|
|
|
| |
Wet bulb temperature, max | 37.7°C (operating) |
|
|
| |
|
| 37.7°C (nonoperating) |
| ||
|
|
| |||
Altitude, operating |
| ||||
|
|
| |||
|
|
| |||
Altitude, nonoperating, max |
| ||||
|
|
| |||
|
|
|
|
| |
Operational Shock, max | 63 Gs at 2 msec |
|
|
| |
|
|
|
|
| |
300 Gs at 2 msec |
|
|
| ||
|
|
| |||
Vibration, operating |
| ||||
|
|
| |||
|
|
| |||
|
|
|
|
|
|
6 | DB35.3 Series PATA Product Manual, Rev. B |