14 | Elite 23 Installation Guide, Rev. A | |||
Table 2: DC power requirements |
|
|
| |
| Differential | |||
| +5V8,10 +12V8 | +5V8,10 +12V8 | ||
Voltage regulation5 | ± 5% | ± 5%2 | ± 5% | ± 5%2 |
|
| Amps |
| |
Maximum starting current |
|
|
|
|
Peak DC 3, 6, 9 | 1.0 | 4.8 | 1.05 | 4.8 |
Delayed motor start (max)1, 4 | .85 | .1 | .85 | .1 |
Peak operating current |
|
|
|
|
Typical DC 1 | .98 | 1.6 | 1.2 | 1.6 |
Maximum (peak)7 | 1.1 | 2.8 | 1.95 | 2.8 |
1Measured with an average reading DC ammeter. Instanta- neous +12V current peaks will exceed these values.
2A
3See the +12V current profile in the Elite 23 Product Manual (publication number 83329140).
4This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command.
5See “Conducted noise immunity” in the Elite 23 Product Man- ual. The specified voltage tolerance is inclusive of ripple, noise, and transient response.