Seagate ST9500323CS, ST9320328CS manual Environmental specifications

Models: ST9500323CS ST9320328CS

1 46
Download 46 pages 42.61 Kb
Page 20
Image 20

• Idle and Standby timers

Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and begins counting down from its specified delay times to zero. If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary.

2.10Environmental specifications

2.10.1Base plate temperature

Actual drive base plate temperature should not exceed 70°C (158°F).

Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.

Operating:

0° to 70°C (32° to 158°F)

 

 

Nonoperating:

–40° to 70°C (–40° to 158°F)

 

 

2.10.2Temperature gradient

Operating

20°C per hour (68°F per hour max), without condensation

 

 

Nonoperating

35°C per hour (95°F per hour max), without condensation

 

 

2.10.3Humidity

2.10.3.1Relative humidity

Operating

5% to 95% noncondensing (30% per hour max)

 

 

Nonoperating

5% to 95% noncondensing (30% per hour max)

 

 

2.10.3.2Wet bulb temperature

Operating

37.7°C (99.86°F max)

 

 

Nonoperating

40°C (104°F max)

 

 

2.10.4Altitude

Operating

–304.8 m to 3,048 m (–1,000 ft. to 10,000+ ft.)

 

 

Nonoperating

–304.8 m to 12,192 m (–1,000 ft. to 40,000+ ft.)

 

 

10

Pipeline HD Mini Series SATA Product Manual, Rev. E

Page 20
Image 20
Seagate ST9500323CS, ST9320328CS manual Environmental specifications