[2]For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9,936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator.

[3]See +12V current profile in Figure 16.

[4]This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.

[5]See paragraph 6.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.

[6]Operating condition is defined as random 8 block reads.

[7]During idle, the drive heads are relocated every 30 seconds to a random location within the band from three-quarters to maximum track.

24

Savvio 10K.4 SAS Product Manual, Rev. A

Page 32
Image 32
Seagate ST9600204SS, ST9600104SS, ST9450304SS, ST9450404SS manual