PREPARATION
Adequate counterspace must be provided for the unit. The area should be easy to reach and be lighted with natural light during the day.
See t he first page for cutout dimensions. Mark the cutout on t he counter. Use a hand or saber saw to make t he cut.
ELECTRICAL CONNECTIONS
Call your Electric Company and ask which codes apply
In your area. If there are no codes, you must follow the
NATIONAL ELECTRICAL CODES, ANSI/NFPA NO. 70- Latest Edition. You can get a copy by wrlUng:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
The counter unit cord has a three prong plug and must be plugged Into a properly grounded three hole outlet. The outlet must be In a standard 120 Volt, 60 Hertz AC household circuit.
Improper grounding can spark Ignition on models so equipped.
Do not under any circumstances cut or remove the grounding prong from the counter unit cord. Failure
to provide proper polarization may cause shock and tire hazard.
If you do not have a grounded three hole outlet, have an electrician change your old outlet or Install a new one.
TO temporarily use a properly polarized and grounded two hole outlet until a grounded three hole outlet can be Installed, a grounding adapter plug may be used. Have an electrician test the outlet to be sure It meets require- ments.
PLUG WITH GROUND PRONG | POLARIZED RECEPTACLE |
PROPERLY POLARIZED AND | PROPERLYGROUNDED |
GROUNDED RECEPTACLE | METAL EYELET |
| |
| GROUND |
| RECEPTACLE |
| PLATE |
| MOUN_NG |
| SCREW |
Fig. 1 | Fig. 2 |
PREFERRED METHOD | TEMPORARY METHOD |
GAS CONNECTIONS
Call your gas supplier and ask which codes apply In your area. If there are no codes, you must follow the NA-
TIONAL FUEL GAS CODE, ANSIiZ223.LStest Edition. You can get a copy by writing:
American Gas Association
1515 Wilson Boulevard
Arlington (Rosslyn), VA 22209 Know where your main gas shut off valve Is.
Shut off gas supply before removing an old range. Leave It off until hookup of new counter unit Is finished.
See figures on this page for rigid and flexible pipe hookups. Some local codes do not allow the use of copper gas pipe. If flexible connectors are allowed,
a new A.G.A. certified flexible connector is rec.
omrnended. Never reuse an old connector when installing a new unit. A manual
supply to the appliance, must be installed in the
gas supply line at anaccessible location in the cabinet below the counter unit.
We recommend that you use 1/2" gas supply line.
1"FROM BACKWALL
.<_121/2,_,_
_ FROMCUTOUT
CENTER UNE
LOCATION OF GAS SUPPLY LINE
FIG.3