![](/images/new-backgrounds/1027733/2773345x1.webp)
SECTION 5
SERVICE TECH INFORMATION
5A.TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This | check | verifies | proper | operation | of | the valve | ||
motor, | brine | tank | fill, brine | draw, | regeneration | |||
flow | rates, | and | other | controller | functions. | Always | ||
make | the | initial | checks, |
| and | the | manual | |
initiated | diagnostics. |
|
|
|
|
|
NOTES: The face plate display must show a steady
time (not flashing). If an Error code shows, first press the #1 SELECT button to enter the diagnostic display.
lo | Press | the | button | and | hold | in | |||||||
| for | 3 | seconds. | RECHARGE |
| NOW | and | FILL | |||||
| begin | to | flash | as | the | softener | enters |
| the | fill | |||
| cycle | of | regeneration. |
| When | FILL | is on steady, | ||||||
| remove |
| the | brinewell | cover | and, | using | a | |||||
| flashlight, | observe | fill | water | entering | the | tank. | ||||||
a. | If | water | does | not | enter the | tank, | look | for | an | ||||
| obstructed | nozzle, | venturi, | fill | flow | plug, | brine | ||||||
| tubing, | or brine valve | riser | pipe. |
|
|
|
|
CYCLE FLOW RATES (GALLONS PER MIN.)
NOTE: If water system pressure is low, an
elevated drain hose may cause back pressure,
stopping brine draw.
3. Again press
softener into backwash. Look for a fast flow of
water from the drain hose.
ao An obstructed flow indicates a plugged top
distributor, backwash flow plug, or drain hose.
o Press
into fast rinse. Again look for a fast drain flow.
Allow the softener to rinse for a few minutes to
flush out any brine that may remain in the resin
tank from the brining cycle test.
o To return the softener to service, press
BRINE VALVE
FLOAT 5ETTIN(_
_t Float
FILL (flow to salt |
| storage tank) | 0.3 | (1.1 | liters) | |
BRINING | "_ | .19 | (.7 | liters) | ||
BACKWASH | I | (flow to drain) | 2.0 | (7.6 | liters) | |
BRINE | RINSE |
| .12 | (,45 | liters) | |
FAST | RINSE |
|
| 2.0 | (7.6 | liters) |
__""- Stop
o After observing fill, press the
button to move the softener into brining. A
slow flow of water to the drain will begin.
Verify brine draw from the brine tank by
shining a flashlight into the brinewell and
observing a noticeable drop in the liquid level.
NOTE: Be sure a salt bridge is not preventing water with salt contact.
ao | If | the softener | does | not | draw | brine • |
|
| |||
| • | nozzle | and/or | venturi | dirty | or defective. |
| ||||
| • | nozzle | and | venturi | not | seated | properly | on | |||
|
| gasket. |
|
|
|
|
|
|
|
|
|
| • | restricted | drain | (check | drain |
| fitting | and |
| ||
|
| hose). |
|
|
|
|
|
|
|
|
|
| • | defective | nozzle |
| and venturi |
| seal. |
|
| ||
| • other | inner | valve | defect | (rotor | seal, | rotor | & | |||
|
| disc, | wave | washer, | etc.). |
|
|
|
|
1F
FREEBOARD MEASUREMENT
(Distance from top of resin tank to top of resin
T | Resin Tank |
FREEBOARD |
|
|
1
Resin Bed