![](/images/new-backgrounds/1027733/2773339x1.webp)
SECTION 5
TROUBLESHOOTING
Keep this manual with your water softener. If repairs
information on the following 8 pages. For telephone
I!!
TRANSFORMER
24VAC
VAC
F
tee _T
I
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1.Does the time display show the correct time of day?
occur at the wrong time.
°Plumbing bypass valve(s) must be in Full Service position.
3.The inlet and outlet pipes must connect to the softener
inlet and outlet respectively,
°Is the transformer plugged into a "live ", grounded wall outlet, and the power cable fastened securely?
5.The valve drain hose must be free of kinks and sharp
bends, and not elevated over 8 ft, above the floor,
SERVICE TECH. INFORMATION
are needed, the service technician must have the
assistance, call toll free,
WIRING SCHEMATIC
NC
_'_POSITION SWITCH
0
NO
Thll
Kenmore
_Teni8
IIMMI b W_mr _
J
REMOVE THE TOP COVER AND SALT TANK COVER
6.Is there salt in the storage tank?
7.Is the brine tubing connected? (See water flow
diagrams).
8. Is the brine valve float set right? (See page 23).
°Press the #l SELECT button 2 times to display the hardness setting. Be sure it is the correct setting for the household _kwater supply. (Make a hardness test of the raw water and compare with the hardness setting. Also test a soft water sample to verify if a problem exists.) Press the #1 SELECT button twice more to return to present time in the display.
If you do not find the problem after making initial checks, do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS, and the MANUAL ADVANCE REGENERATION CHECK.
_N