Trouble Shooting

Trouble Shooting

PROBLEM

EVIDENCE

SOLUTIONS(S)

 

 

 

Low Humidity

Low water level (less than

• See Plumbing and Setting Water

 

2-3/8" deep)

Level, steps 4 & 5

 

No water in reservoir

• Turn water on at saddle valve

 

 

• Turn off water main and check

 

 

for possible obstruction in saddle

 

 

valve or float valve

 

Humidifier heater is not

• Make sure the humidifier is

 

operating

plugged in

 

 

• Set the humidistat higher

 

 

• Check for blown circuit breaker

 

 

• Check all external wiring connec-

 

 

tions

 

 

• Check for low water level

 

 

• Check the humidistat switch for

 

 

continuity

 

 

• Call a professional HVAC con-

 

 

tractor

 

Rapid air changes (drafts)

• Keep doors and windows closed

 

 

(cold, dry air is an added load

 

 

on the humidifier)

 

 

• Close fireplace damper when

 

 

not in use

 

 

• Keep exhaust fan running time

 

 

to a minimum

 

 

• Seal around doors and windows

High Humidity

Condensation on walls

• Turn humidistat off

 

 

• Turn water to humidifier off

 

 

until condensation is evaporated

 

Heavy condensation on

• Turn humidistat down enough

 

windows

to eliminate condensation (this

 

 

may be a temporary condition

 

 

caused by moisture from bathing,

 

 

mopping, cooking, etc.)

Humidifier Overflows

High water level

• Inspect valve seat for defects

 

 

• Inspect valve nozzle for cracks

 

 

or erosion

 

 

• Readjust water level (see

 

 

Plumbing and Setting Water

 

 

Level

 

 

• Make sure humidifier is level

 

 

 

Table 1

 

 