![Trouble Shooting](/images/new-backgrounds/54906/5490653x1.webp)
Trouble Shooting
PROBLEM | EVIDENCE | SOLUTIONS(S) |
|
|
|
Low Humidity | Low water level (less than | • See Plumbing and Setting Water |
| Level, steps 4 & 5 | |
| No water in reservoir | • Turn water on at saddle valve |
|
| • Turn off water main and check |
|
| for possible obstruction in saddle |
|
| valve or float valve |
| Humidifier heater is not | • Make sure the humidifier is |
| operating | plugged in |
|
| • Set the humidistat higher |
|
| • Check for blown circuit breaker |
|
| • Check all external wiring connec- |
|
| tions |
|
| • Check for low water level |
|
| • Check the humidistat switch for |
|
| continuity |
|
| • Call a professional HVAC con- |
|
| tractor |
| Rapid air changes (drafts) | • Keep doors and windows closed |
|
| (cold, dry air is an added load |
|
| on the humidifier) |
|
| • Close fireplace damper when |
|
| not in use |
|
| • Keep exhaust fan running time |
|
| to a minimum |
|
| • Seal around doors and windows |
High Humidity | Condensation on walls | • Turn humidistat off |
|
| • Turn water to humidifier off |
|
| until condensation is evaporated |
| Heavy condensation on | • Turn humidistat down enough |
| windows | to eliminate condensation (this |
|
| may be a temporary condition |
|
| caused by moisture from bathing, |
|
| mopping, cooking, etc.) |
Humidifier Overflows | High water level | • Inspect valve seat for defects |
|
| • Inspect valve nozzle for cracks |
|
| or erosion |
|
| • Readjust water level (see |
|
| Plumbing and Setting Water |
|
| Level |
|
| • Make sure humidifier is level |
|
|
|
Table 1 |
|
|
CONTRACTOR
27