Mounting the Humidifier

Figure 1 - Duct Edge Mount

Option A: Duct Edge Mount

Option A is the preferred method of mounting because it requires the least amount of duct reinforcement to support the humidifier and keep it level. A duct width of at least 10 inches is necessary. Wider ducts may need to be reinforced in order to hold the humidifier level.

DANGER: Wear safety glasses when cutting or drilling. Do not cut into any air conditioning or electrical accessories during installation.

Electrocution is possible if you come in contact with a live electrical wire; blindness can occur if Freon contacts your eyes.

To install:

1.Fold the humidifier mounting template along the line marked “FOLD LINE”. Attach the template so the top/front is located on the side of the duct, and the remainder of the template is on the bottom of the duct.

2.Drill three (3) holes marked “A” with a 7/64" drill bit. Drill a hole in the center of the shaded area of the template and remove the shaded area using tin snips.

CAUTION: Follow the dotted line carefully.

10

Page 10
Image 10
Skuttle Indoor Air Quality Products 60-2, F60-2 warranty Mounting the Humidifier, Duct Edge Mount