MAINTENANCE AND TROUBLE-SHOOTING
Inspect and tighten all parts of the CARDIO FIT at least every three months. Keep the monitor out of direct
sunlightor the LCD display may be damaged. The monitor can be cleaned using a soft, dry cloth. Do not allow
liquidto come in contactwith the monitor•Remove the batteries when storingthe CARDIO FIT.
REPLACING THE BATI'ERIES
if the display of the Monitor(1) becomes dim, the two Ll154
watch batteries should be replaced. Remove the #8 x 1/2"
Screw (16) from the back ofthe Monitor. Remove the two
screwsfrom the back cover of the Monitor and remove the
back cover. Push the two old batteries out of the clips, and
insed two newbatteries,
Reattech the back cover and reattach the Monitor (1) to the
Frame (6). Make sure that thewire on the Monitor isplugged
into the sensorwire. Insed any excess wire intothe Frame.
Make sure notto pinchthe wire between the Frame andthe
Monitor.
ADJUSTING THE MAGNET AND REED SWITCH
Ifthe monitor does not function propedy, the Magnet (27) and
Reed Switch (15) should be checked. Pivotthe Pedal Frame
(7) until the Magnet is aligned with the Reed Switch. Loosen
the #8 x 3/4" Screw (18) andslide the ReedSwitch toward
the Magnet untilthere is a 1/8" gap between the Magnet and
the Reed Switch. Retighten the Screw.
LUBRICATING THE CARDIO FIT
The ends of the Link Arms (4) should be oiled every six
months.Apply a few dropsof light multi-purpose oil between
the Unk Arms and the domecaps in the indica.tedlocations.
Apply Oil
8