Sebo G-SERIES manual Trouble-ShootingGuide, Page

Models: G-SERIES

1 14
Download 14 pages 3.9 Kb
Page 10
Image 10
Trouble-Shooting Guide

Trouble-Shooting Guide

!Always unplug vacuum from outlet before dismantling any part of the machine!

PROBLEM

REASON

SOLUTION

 

 

 

 

Does not turn on

1. Handlenot fully inserted into the bag

1.

Release handle catch, push handle

or machine shuts off

 

housing, causing a faulty connection.

 

down, close handle catch.

intermittently

 

 

 

 

2.

Not plugged into good outlet.

2.

Use another outlet.

 

 

 

 

 

 

 

3.

Cable worn.

3.

Replace cable.

 

 

 

 

 

 

4.

Dust bag housing (6) not seated

4.

Housing release button (8) should

 

 

fully into proper “locked” position

 

be snapped outward to its locked

 

 

on top of power head.

 

position.

 

 

 

Bag full or clog light on

1. Bag full.

1. Replace bag. See #5 on page 4.

or flashing &

 

 

 

 

2.

Clog in airflow pathway, attach-

2.

See Clog Removal on page 9.

machine shuts off

 

ment hose, attachment tube, swivel

 

Also, see #5 on page 4.

(red light A see page 7,

 

 

 

neck or entrance to dust bag.

 

 

figure 7)

 

 

 

 

 

 

 

 

3.

Microfilter dirty.

3.

Replace microfilter.

 

 

 

Brush light on

1. Brush worn.

1. Replace brush. See #3 on page 4.

(red light B see page 7,

 

 

 

 

2.

Incorrect brush setting

2.

Adjust the brush by turning the pile

figure 7)

 

 

 

 

adjustment knob up or down.

 

 

 

Brush light slowly

1. Vacuum is stationary and in

1. See #4 on page 4.

flashing (red light B)

 

upright locked position.

 

 

 

 

 

Brush light flashing &

1. Brush jammed or clogged.

1. Clear jam. See #2 on page 4.

machine shuts off

 

 

 

 

2.

Brush is too low for the surface

2.

Raise the brush by turning the pile

(red light B)

 

 

being vacuumed.

 

adjustment knob up.

 

 

 

 

 

Does not pick up

1.

Attachment tube not

1.

Reinsert attachment tube, making

 

correctly inserted.

 

sure lower end of tube is in the

 

 

 

 

 

 

 

lower hole and handle is properly

 

 

 

 

seated over the projection tab (23).

 

 

 

 

 

 

2.

Front cover not closed.

2.

See below.

 

 

 

 

 

Front bag door won’t

1.

Cover release flap not fully closed.

1.

Reinsert bag. Lock the cover

fully close

 

 

 

release flap down firmly.

 

 

 

 

 

 

2.

Bag not inserted properly

2.

Reinsert bag with cover release

 

 

 

 

flap (5) up, until firmly latched in

 

 

 

 

bag holder (see pg. 8, figure 9).

 

 

 

 

 

 

3.

Microfilter not properly inserted.

3.

Lift safety lever and insert filter with

 

 

 

 

vertical plastic ridge on filter facing

 

 

 

 

you (see pg. 8, figure 10).

 

 

 

 

 

Hose doesn’t retract

1.

Attachment tube not properly

1.

Reinsert making sure top of handle

after attachment tube is

 

inserted.

 

is pointing back and tube is fully

 

 

 

seated on the protruding tab (23)

inserted

 

 

 

 

 

 

on top of the dust bag housing.

 

 

 

 

 

 

 

 

 

Page 10

Page 10
Image 10
Sebo G-SERIES manual Trouble-ShootingGuide, Page