Lock Status Jumper:

ENFORCER Delayed Egress Timer

Lock Status Jumper:

When the lock status jumper is ON, the lock status input will detect whether the door is closed and will trigger relock functions.

The lock status input may be bypassed in order to keep the door unlocked for an indefinite period of time without activating the remote alarm output.

To bypass the lock status input, set jumper 1 to OFF.

The lock status input must be ON for BOCA Mode (See pg. 5, Relock Modes).

Default: OFF

Jumper 1

Security Mode Jumper:

To activate security mode, set jumper 2 to ON.

In security mode, after the initiate device (such as a push-to-exit bar) has been triggered and the pre-delay timer has ended, the lock will remain active until the initiate device has been triggered a second time.

When security mode is OFF, the initiate device must only be activated once.

Default: OFF

Jumper 2

Local Alarm Output Type Jumper:

The SA-025EQ is equipped with a 500mA@12VDC transistor ground output for a local alarm, typically an audible or visual device.

The local alarm output can be set for steady or pulsing. When set ON, the local alarm pulses during the pre-delay, gradually pulsing faster until the end of the pre-delay time. The local alarm will continue signaling steady 5 seconds after the lock has been released. When set OFF, the local alarm is steady during the pre-delay time and for 5 seconds after the lock has been released.

LED 4 is on when the local alarm output is active.

The local alarm signals when the pre-delay bypass is used (see pg. 9).

To set the local alarm output type ON (steady) or OFF (pulsing), use jumper 3 on the right side of the circuit board.

Default: OFF

Jumper 3