ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

WIRING, BASIC DIAGRAM

The ENFORCER SK-1123-FQ has backlit keys that can be programmed for different applications. The keypad can be always illuminated (FULL), or illuminated only during user activity (AUTO). To verify or change the settings, refer to the table below.

 

 

 

 

 

 

 

 

 

 

 

Back-lit jumper

 

1

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAP Jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

N.C. tamper

 

 

 

 

Interlock—NPN transistor, used

 

 

 

 

 

 

 

 

 

 

with second keypad2

 

 

 

 

 

 

 

 

 

 

 

(-) N.O. Output 1 inhibit3

 

N.C. tamper

 

 

 

12~24V

(+)

 

 

 

 

 

 

 

 

(-) N.C. Door position sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(-) Common ground—for use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VAC/VDC

(-)

 

 

 

 

 

 

 

 

with interlock function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EGRESS IN

 

 

 

(-)Egress—N.O. ground 4

 

N.C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duress output—Transistor

 

 

 

 

 

 

 

 

 

 

 

Output 1

COM

 

 

 

 

ground (-) 100mA@24VDC

 

 

 

 

 

 

 

 

 

 

 

(-) N.O. output 2

 

N.O.

 

 

 

 

 

Back-Lit Jumper

Setting

Jumper Position

Description

 

 

 

 

 

 

 

 

Keypad standby mode is dimly backlit.

FULL

 

 

 

 

 

 

 

Keypad brightens to full illumination for 10 seconds

(default)

 

 

 

 

 

 

 

after each key is pressed, then returns to dim backlit

 

1

2

3

 

 

 

 

 

 

(standby mode).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keypad standby mode is not lit.

AUTO

 

 

 

 

 

 

 

Keypad brightens to full illumination for 10 seconds

 

 

 

 

 

 

 

after each key is pressed, then turns off again

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

 

 

 

 

(standby mode).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1For DC, connect to a regulated power supply. Polarity of the regulated power supply must be correct. For AC, polarity is not important.

2Mantrap control output – Outputs ground (-) for five seconds after relay output #1 is activated, continues while the door is open.

3Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.

4Connect to optional N.O. push button or switch.

Page 4

SECO-LARM® U.S.A., Inc.

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

PREPARING TO PROGRAM THE KEYPAD

To program the SK-1123-FQ, first determine the following information:

1.The master code Allows the system administrator to program or operate the keypad.

2.The user code or codes – Allows users to use the keypad’s functions. Use the chart on pages 8 and 9 to organize.

3.Configuration of the relays and outputs For relay output #1 and output #2, determine whether the output should operate from 1 to 999 seconds and then turn OFF (momentary mode), or turn

ON/OFF via the code (shunt mode). Use the chart on pages 8 and 9 to organize.

4. Result of improper code entry (optional) Choose between a 30-second code lockout, duress output, a 15-minute code lockout, or no reaction.

*Note: When x x x x appears in the instructions, it indicates master code entry.

GETTING STARTED

A master code is required to program the keypad. The default master code is set to ―0000.‖ To change a forgotten master code, go to page 15 and follow the instructions for ―MASTER CODE BYPASS‖

(DAP jumper).

Once the master code is set, review the programming options and decide exactly what the keypad will do, including the format of the user access codes as well as how the keypad responds via the relay output, buzzer and LEDs. Note that in every case the basic steps for programming are:

1.Enter the master code, followed by the key, which puts you in programming mode.

2.Enter the programming options defined in the various sections as needed, followed by the # key.

3.Enter the key again to exit programming mode.

Note: A rapid string of 5 beeps and/or 5 LED flashes indicates an error, while 2 beeps indicates that the entry has been accepted.

USER PROGRAMMING

ENTER PROGRAMMING MODE

Enter Master Code

Confirm

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

x

 

x

 

x

 

 

 

 

Enter into programming mode

 

 

 

 

 

 

 

 

 

 

 

 

ADDING OR CHANGING MASTER AND USER CODES

WARNING – Press the correct option key. If the option key is not used and a “0” is pressed after entering the Master Code, it could accidentally reprogram the Master Code.

Option

User ID

Access Code

Confirm

Function

 

 

 

 

4 to 8 digits

 

 

 

 

 

0

 

 

 

#

 

Change Master Code

 

 

00 to 99

4 to 8 digits

 

 

Set/change up to 100 User Codes for output #1, with duress feature

 

1

 

 

#

 

 

 

0 to 9

4 to 8 digits

 

 

Set/change up to 10 User Codes for output #2

 

2

 

 

#

 

Note: User D must be entered for options 1 and 2.

DELETE A USER

To delete a user who no longer has authority to enter the protected area:

Option

User ID

Confirm

Function

 

 

 

00 to 99

 

 

 

Deletes specific user ID from output #1

 

1

 

 

#

 

 

 

0 to 9

 

 

Deletes specific user ID from output #2

 

2

 

 

#

 

Note: User D must be entered for options 1 and 2.

EXIT THE PROGRAMMING MODE BY PRESSING THE * KEY

SECO-LARM® U.S.A., Inc.

Page 13

Page 4
Image 4
SECO-LARM USA SK-1123-FQ warranty Back-Lit Jumper, SECO-LARM U.S.A., Inc, Getting Started, User Programming

SK-1123-FQ specifications

SECO-LARM USA has established itself as a trusted name in the security industry, providing innovative solutions tailored for various applications. One of their standout products is the SECO-LARM SK-1123-FQ, a sophisticated yet user-friendly accessory designed to enhance security systems for both residential and commercial properties.

The SK-1123-FQ is a magnetic door switch, known for its reliability and effectiveness in providing intrusion detection. Its primary function is to alert users when a door or window has been opened, triggering an alarm or activating a security system. Built with high-quality materials, the SK-1123-FQ boasts a rugged construction that ensures durability even in harsh outdoor conditions.

One of the key features of the SECO-LARM SK-1123-FQ is its compact size, which makes installation straightforward and unobtrusive. The switch itself includes a mounting bracket that allows for versatile placement options on doors or windows. This adaptability is essential for users looking to integrate the switch seamlessly into existing security installations.

The unit operates on a normally open circuit, making it compatible with most existing alarm systems. It utilizes a reed switch mechanism, providing a high level of sensitivity and minimizing the chances of false alarms. Additionally, the maximum operating distance between the magnet and the switch is approximately 20mm, which is sufficient for standard installations.

One notable technological aspect of the SK-1123-FQ is its low power consumption, allowing it to be used in battery-operated settings without the worry of draining power resources quickly. This feature is particularly beneficial for remote installations where power sources may be limited.

Another important characteristic of the SK-1123-FQ is its versatility; it can be used in various applications including home security, commercial premises, and industrial facilities. Whether protecting entry points or monitoring access to sensitive areas, this door switch provides a reliable solution.

In summary, the SECO-LARM USA SK-1123-FQ magnetic door switch combines durability, ease of installation, and reliability to create an effective security measure. Its numerous features and technological enhancements make it an excellent choice for anyone looking to bolster their security systems, ensuring peace of mind and enhanced protection against unauthorized access.