ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

 

 

 

 

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

WIRING

 

 

 

 

 

 

5. Door-Hold-Open Mode

 

Example Wiring, 2 Keypads with Mantrap Interlock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For N.C. locking devices: Connect a relay

For N.O. locking devices: Connect a relay to

 

DOOR #1

Diode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1N400

4

Door #2 sensing

 

to output 2 in series with the locking device.

output 2 in parallel with the locking device.

 

 

Cathode

 

 

 

SM-200

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric

 

Lock #1

 

 

N.C.

12~24V

 

AC/DC

 

power

 

supply

 

 

Crosswire

 

connection for

 

interlock

 

functions

Egress button

N.O.

(Open door #2

from inside)

 

DOOR #2

Common

WIRING – Example Wiring, with Connection to Lock Device

ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12~24V

 

 

 

 

 

 

 

 

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC/DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door #2 sensing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SM-200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric Lock #2

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Egress button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Open door #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diode

 

from inside)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1N4004

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cathode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantrap (Interlock) – Each keypad can be used as a stand-alone keypad. The mantrap feature

is

 

 

 

 

 

 

 

 

for a protected area with two doors to ensure only one door can be opened at a time. With the

 

 

 

 

 

 

 

 

mantrap feature enabled, when a user opens one door either by entering a code or with a request-

 

 

 

 

 

 

 

 

to-exit button, a signal is sent to the second keypad to disable it, thereby preventing access through

 

 

 

 

 

 

 

 

the second door until the first door is closed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use an N.C. magnetic contact or some other N.C. device to detect whether a door is opened or

 

 

 

 

 

 

 

 

 

closed. Do this for the two doors being protected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combine this wiring diagram with the diagram on page 7 if connection to an alarm control panel

 

 

 

 

 

 

 

 

 

is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.O. Egress button

 

 

 

To use the mantrap feature:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Open door from inside)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Additional egress buttons

 

 

 

o Use either the keypad from outside or the egress button from inside the protected premises

 

 

 

 

 

can be connected in parallel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

 

 

 

 

 

 

to open one of the two doors.

 

 

 

 

 

 

 

 

 

 

 

For DC use only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

o While the first door is opened, the first keypad sends a signal to the second keypad to

 

Connect the duress output to a 24-hour N.O. zone and the tamper output to a 24-hour N.C.

 

prevent the second door from being opened.

 

 

 

 

 

 

 

 

 

 

zone on the alarm control panel.

 

 

 

 

o Once the first door is closed, both doors are ready to open again.

 

 

 

 

 

 

The keypad’s terminal ground (-) connects to the ground (-) wire of the alarm control panel to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

enable the two to work together.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 