ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

OUTPUT 2 (NPN TRANSISTOR OPEN COLLECTOR)

The Output 2 is an NPN transistor open collector output controlled by User Code 2, and can be used for some auxiliary controls. It is equivalent to an N.O. output rated 100mA @24VDC.

1. Shunting an N.C. Protection Zone

Use output #2 to shunt an N.C. protection zone.

Set output #2 to ON/OFF Mode (See pg.14, section 3, programming option 51).

2. Alarm System Arm-Disarm Control

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

WIRING Auxiliary Accessories

1. Tamper N.C.

When the keypad is secured in the single-gang box, the tamper switch is in the closed position. When the keypad is removed, the tamper switch will open. Connect the terminals to a 24-hour N.C. alarm system protection zone if required.

2. Door Sensing

a) Auto Relock – The door will relock after granting access to prevent ―tailgate‖ entries.

 

 

 

 

 

Terminals in Alarm

 

 

 

 

 

Control Panel for

 

 

 

 

 

Connecting Remote

 

 

 

 

 

Arm-Disarm Control

NC or

 

NO

 

 

 

 

 

Switch

 

 

 

 

 

NO or NC Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM CONTROL PANEL

Refer to your alarm control panel manual to determine whether the arm- disarm control is NC or NO.

Set output #2 to momentary mode for multi station systems or ON/OFF mode for single-station systems. See page 14, section 3 for programming options.

b) Forced-Open Alarm – Alarm will go off instantly if the door is forced open. Enable this function with programming option 801 (found on pg.14).

c) Door-Propped-Open Alarm – Alarm will go off if the door is left open longer than the programmed delay time. Enable this function with programming option 9 (1~999 seconds).

3. Drive an Optional Output Relay

Use a 12VDC relay and connect it to the same 12V power supply as the keypad.

d) Mantrap (Interlock) Control – When the door is open, the interlock output of the keypad will switch to ground to disable the other keypads.

3. Duress Output

4. Connecting Inhibit Control

WARNING

Make sure nobody is inside the house before starting the door lock inhibit function.

The inhibit authorization code should always be kept by only the owner.

Using this setup, the owner may enter the user code for output #2 to disable output #1 during a certain period to prevent unauthorized access.

Set output #2 to ON/OFF mode

(pg.14, section 3, programming option 51). Connect the O/P 1 INHIB terminal with the

O/P 2 N.O. terminal as shown in wiring diagram. User code #1 is invalid while the O/P 1 INHIB terminal is shunted to ground via user code #22.

Duress

Output

OR

When a duress code is entered, the duress output will switch to (-) ground. It can trigger a connected LED lamp or small buzzer to notify a guard, or connect it to a 24 hour N.O. alarm system protection zone.

NOTE: Only one connection option is recommended. Output current must not exceed 100mA.

Page 6

SECO-LARM® U.S.A., Inc.

SECO-LARM® U.S.A., Inc.

Page 11

Page 6
Image 6
SECO-LARM USA SK-1123-FQ Shunting an N.C. Protection Zone, Alarm System Arm-Disarm Control, Tamper N.C, Door Sensing

SK-1123-FQ specifications

SECO-LARM USA has established itself as a trusted name in the security industry, providing innovative solutions tailored for various applications. One of their standout products is the SECO-LARM SK-1123-FQ, a sophisticated yet user-friendly accessory designed to enhance security systems for both residential and commercial properties.

The SK-1123-FQ is a magnetic door switch, known for its reliability and effectiveness in providing intrusion detection. Its primary function is to alert users when a door or window has been opened, triggering an alarm or activating a security system. Built with high-quality materials, the SK-1123-FQ boasts a rugged construction that ensures durability even in harsh outdoor conditions.

One of the key features of the SECO-LARM SK-1123-FQ is its compact size, which makes installation straightforward and unobtrusive. The switch itself includes a mounting bracket that allows for versatile placement options on doors or windows. This adaptability is essential for users looking to integrate the switch seamlessly into existing security installations.

The unit operates on a normally open circuit, making it compatible with most existing alarm systems. It utilizes a reed switch mechanism, providing a high level of sensitivity and minimizing the chances of false alarms. Additionally, the maximum operating distance between the magnet and the switch is approximately 20mm, which is sufficient for standard installations.

One notable technological aspect of the SK-1123-FQ is its low power consumption, allowing it to be used in battery-operated settings without the worry of draining power resources quickly. This feature is particularly beneficial for remote installations where power sources may be limited.

Another important characteristic of the SK-1123-FQ is its versatility; it can be used in various applications including home security, commercial premises, and industrial facilities. Whether protecting entry points or monitoring access to sensitive areas, this door switch provides a reliable solution.

In summary, the SECO-LARM USA SK-1123-FQ magnetic door switch combines durability, ease of installation, and reliability to create an effective security measure. Its numerous features and technological enhancements make it an excellent choice for anyone looking to bolster their security systems, ensuring peace of mind and enhanced protection against unauthorized access.