ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

PROGRAMMING NOTES

1.Master Code: The SK-1123-FQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or data should be programmed at the owner’s discretion. However, to ensure security, program a new Master Code to replace the factory-set Master Code as soon as possible.

2.Factory defaults:

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

SPECIFICATIONS

Power:

Operating voltage 12~24 Volts AC/DC. No jumper needed to set voltage. Stand-by current drain 10mA@12VDC.

Master code

0000

User code length

4-8 digits

 

 

Output #1 time

1 second

 

 

Output #2 time

1 second

Wrong code lockout

10 tries / 30 sec.

 

 

Door-forced-open alarm

Disabled

 

 

Door-forced-open alarm

Disabled

Door unlocked annunciation

ON

 

 

User code entry mode

Manual

 

 

Keypress beep

ON

Door-propped-open alarm

OFF

 

 

Silent operation

OFF

 

 

Active current drain (press keypad key) Under 45mA@12VDC.

Active current drain (one relay activated) Under 100mA@12VDC.

Outputs:

Output #1 – 5A@30VDC max. rating, Form ―C dry contact‖, NO/COM /NC. Programmable for 1 to 999 second timed output or shunt (ON/OFF) output. Three terminals.

3.Code operation: User codes are each four to eight digits and are assigned a two-digit ID. If all the codes have the same number of digits, the keypad can be programmed for auto code checking. The # key need not be pressed after entering a code (see programming option 82, page 14, section 7).

The administrator can easily delete the code of a single user via the two-digit ID if the user is no longer authorized to enter a protected area.

Relay output #1 allows up to 100 user codes, and output #2 allows up to 10 user codes.

4.Using Duress codes (relay output #1 only): Duress codes are used to activate a separate device silently to alert a guard or other personnel that a user is operating the keypad under threat. The keypad operates as normal, but a silent signal is sent to alert others.

Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code.

For example:

User code 4468 can be entered as duress code 6468 User code 9843 can be entered as duress code 1843 User code 8181 can be entered as duress code 0181

NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user code. For example:

If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot be programmed.

Note: Once activated, the duress output continues until a correct user code is entered.

LED INDICATORS

Red LED – Illuminates while output #2 is activated.

Amber LED – Flashes to show the keypad status (see below).

Green LED – Illuminates while output #1 is activated.

BUZZERS AND LED SIGNALS

 

 

 

 

Red Amber Green

 

STATUS

BUZZER TONES*

AMBER LED FLASHES

1.

In programming mode

---

ON

 

 

 

 

 

 

2.

Successful key entry

1 beep

1 flash

 

 

 

 

 

 

3.

Successful code entry

2 beeps

2 flashes

 

 

 

 

 

 

4.

Unsuccessful code entry

5 beeps

5 flashes

 

 

 

 

 

 

5.

DAP jumper not replaced

Continuous beeps

Continuous flashes

 

 

 

 

 

 

6.

In standby mode

---

1 flash in 2-sec intervals

 

7.

Output relay activated

1-sec long beep**

---

 

 

 

 

 

 

NOTE: *The buzzer can be disabled through programming option 83, see pg. 14, section 8.

**The output relay activated beep can be disabled through programming option 81, see pg. 14, section 6.

Output #2 100mA@24VDC max. rating. Transistor ground output programmable for 1 to 999 second momentary output or shunt (ON/OFF) output. One terminal.

Mantrap (interlock) control output 100mA@24VDC. NPN open collector switches to ground (-) for five seconds after relay output #1 is activated, continues while the door is open. Use to disable a second keypad during this time. Single terminal.

Duress output 100mA@24VDC. NPN open collector switches to ground when active. Single terminal.

Inputs:

Power 12~24 Volts AC/DC. Two terminals. Egress N.O., ground (-). Single terminal.

Door sensor input N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or closed, or connect to ground (-) if not used. Single terminal.

Relay output #1 disable input Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active. Single terminal.

Other Features:

Tamper 50mA max., N.C. dry contact. Connect to the tamper circuit of alarm control panel. Two terminals.

Common ground (-).

Code Operation:

Auto or manual code entry. Up to 100 user codes for output #1, up to 10 user codes for output #2. Over 100 million possible user code combinations.

Auto Reset Time During Code Entry:

Max. 10 seconds to enter each digit.

Max. 30 seconds to enter each code.

Dimensions:

43/4‖x31/8‖x115/16‖ (120x80x46 mm)

Weight:

11-oz (300g)

Page 12

SECO-LARM® U.S.A., Inc. SECO-LARM® U.S.A., Inc.

Page 5

Page 5
Image 5
SECO-LARM USA SK-1123-FQ warranty Enforcer FLUSH-MOUNT Outdoor Access Keypad, LED Indicators, Buzzers and LED Signals

SK-1123-FQ specifications

SECO-LARM USA has established itself as a trusted name in the security industry, providing innovative solutions tailored for various applications. One of their standout products is the SECO-LARM SK-1123-FQ, a sophisticated yet user-friendly accessory designed to enhance security systems for both residential and commercial properties.

The SK-1123-FQ is a magnetic door switch, known for its reliability and effectiveness in providing intrusion detection. Its primary function is to alert users when a door or window has been opened, triggering an alarm or activating a security system. Built with high-quality materials, the SK-1123-FQ boasts a rugged construction that ensures durability even in harsh outdoor conditions.

One of the key features of the SECO-LARM SK-1123-FQ is its compact size, which makes installation straightforward and unobtrusive. The switch itself includes a mounting bracket that allows for versatile placement options on doors or windows. This adaptability is essential for users looking to integrate the switch seamlessly into existing security installations.

The unit operates on a normally open circuit, making it compatible with most existing alarm systems. It utilizes a reed switch mechanism, providing a high level of sensitivity and minimizing the chances of false alarms. Additionally, the maximum operating distance between the magnet and the switch is approximately 20mm, which is sufficient for standard installations.

One notable technological aspect of the SK-1123-FQ is its low power consumption, allowing it to be used in battery-operated settings without the worry of draining power resources quickly. This feature is particularly beneficial for remote installations where power sources may be limited.

Another important characteristic of the SK-1123-FQ is its versatility; it can be used in various applications including home security, commercial premises, and industrial facilities. Whether protecting entry points or monitoring access to sensitive areas, this door switch provides a reliable solution.

In summary, the SECO-LARM USA SK-1123-FQ magnetic door switch combines durability, ease of installation, and reliability to create an effective security measure. Its numerous features and technological enhancements make it an excellent choice for anyone looking to bolster their security systems, ensuring peace of mind and enhanced protection against unauthorized access.