MIB Descriptions

Table C-10. Synchronous Port Table Objects (2 of 2)

Object

Description

Setting/Contents

 

 

 

rs232SyncPort

Reports the interval (in

Supports only the following read-only

RTSCTSDelay

milliseconds) that the port

value:

(rs232Sync

waits after RTS is asserted

integer number ± represents

PortEntry 11)

before asserting CTS.

milliseconds. It is only valid for the user

 

 

 

 

data port, when Carrier Control by RTS

 

 

is set to Switched and corresponds to

 

 

approximately 21 bit time intervals at the

 

 

operating DDS rate.

 

 

 

rs232SyncPort

Specifies the port's mode of

Supports only the following value:

Mode

data transfer.

fdx(1) ± Full-duplex

(rs232Sync

 

 

 

PortEntry 12)

 

 

 

 

 

The following are not supported:

Hrs232SyncPortIdle Pattern (rs232SyncPortEntry 13)

Hrs232SyncPortMinFlags (rs232SyncPortEntry 14)

Input Signal Table Objects

The Input Signal Table contains entries for the input signals that can be detected by the unit for the synchronous user data port. Clarification for objects contained in this table as it applies to the unit is provided in Table C-11.

Table C-11. Input Signal Table Objects

Object

Description

Setting/Contents

 

 

 

rs232InSigName

Contains the identification

Supports only the following values:

(rs232InSigEntry 2)

of a hardware input signal.

rts(1) ± Request To Send

 

 

 

 

dtr(4) ± Data Terminal Ready

 

 

 

rs232InSigState

Contains the current signal

Supports only the following values:

(rs232InSigEntry 3)

state.

on(2) ± The signal is asserted

 

 

 

 

off(3) ± The signal is deasserted

 

 

 

rs232InSigChanges

Indicates the number of

The object is incremented each

(rs232InSigEntry 4)

times that a signal has

time that the signal is sampled

 

changed from on to off, or

(every 100 ms) and the signal state

 

off to on.

is different from the previous state.

 

 

 

C-16

November 1997

7612-A2-GB20-10

Page 102
Image 102
Paradyne 7612 SNMP DSU Input Signal Table Objects, Rs232SyncPortMinFlags rs232SyncPortEntry, Integer number ± represents

7612 SNMP DSU specifications

The Paradyne 7612 SNMP DSU (Data Service Unit) is a robust and versatile device designed for effective communication in data networks. This device is particularly suited for businesses that require reliable connectivity to support their operations. The 7612 integrates advanced technologies that enhance performance, scalability, and ease of management.

One of the main features of the Paradyne 7612 is its support for SNMP (Simple Network Management Protocol), which allows for comprehensive monitoring and management of network devices. This capability ensures that network administrators can easily track performance metrics and troubleshoot issues in real time, thereby minimizing downtime and enhancing overall operational efficiency.

The 7612 also provides multiple interface options, including T1/E1 and fractional T1, enabling users to select the most suitable bandwidth for their specific requirements. With full duplex capabilities, the device can handle simultaneous data transmission and reception, ensuring efficient communication and high throughput.

In terms of security, the Paradyne 7612 incorporates features such as port security and access control lists (ACLs). These measures protect the network from unauthorized access, ensuring that sensitive data remains secure during transmission. Additionally, the DSU incorporates intelligent diagnostic features, such as loopback testing and error monitoring, enabling proactive identification and resolution of network issues.

The device is built with a modular design, allowing for easy upgrades and scalability as business needs grow. This flexibility ensures that organizations can adapt their network infrastructure without the need for significant overhauls or extensive downtime.

The Paradyne 7612 also boasts an intuitive web-based user interface, simplifying configuration and management tasks. Network administrators can access settings and monitor performance from any location, streamlining network management processes.

With a focus on reliability, the 7612 is designed to operate in various environmental conditions, offering features such as extended temperature ranges and robust construction, making it suitable for deployment in both indoor and outdoor settings.

In summary, the Paradyne 7612 SNMP DSU stands out in the realm of data communication devices with its advanced SNMP capabilities, versatile interface options, robust security features, modular design, and user-friendly management interface. These characteristics make it an ideal solution for enterprises seeking to maintain reliable, scalable, and secure data communication networks.