Configuration Option Tables

A-9

7612-A2-GB20-10 November 1997
Table A-3. Data Port Options (3 of 3)
Monitor DTR
Possible Settings: Enable, Disable
Default Setting: Enable
Indicates to the DSU whether to monitor the Interchange Circuit CT108, Data Terminal
Ready (DTR), from the DTE.
Enable – The DSU monitors the state of DTR on the User Data (DTE) port. Based on
the Link Traps option setting in Table A-9, the DSU uses the DTR circuit to trigger a Link
Up/Down SNMP trap and a Health and Status message.
Disable – DTR is not monitored by the DSU. Use when a DTE does not provide the
DTR lead at the interface.
Ethernet Port Options Menu
For Ethernet Port Options, refer to Table A-4. To access the Ethernet Port
Options screen, follow this menu selection sequence:
Main Menu
Configuration
Load Configuration From
Edit

Ethernet Port

Table A-4. Ethernet Port Options (1 of 2)
Port Use
Possible Settings: 802.3, Version 2, Disable
Default Setting: Version 2
The Ethernet port provides a choice of functions.
802.3 – Configures the DSU to use IEEE 802.3 format.
Version 2 – Configures the system to use Ethernet Version 2 format.
Disable – Data received on this port is ignored.
No other fields in this table will appear when set to Disable.
IP Address
Possible Settings: 000.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the IP (Internet Protocol) address used to identify the Ethernet port. Each
three-digit decimal number represents a byte.
000.000.000.000 – 223.255.255.255 – Enter an address. The range for the first byte is
000 to 223, with the exception of 127. The range for the remaining three bytes is 000 to
255.
Clear – Clears the IP Address and sets to all zeros.