MIB Descriptions
C-11
7612-A2-GB20-10 November 1997

Table C-6. IP Group Objects (2 of 2)

Object Setting/ContentsDescription
ipRouteTable

(ip21)

(Continued)
ipRouteIfIndex – If this object has a
greater value than the ifNumber, then
it refers to a proprietary interface not
currently implemented by the MIB II
Interface Group. Do not delete route
entries with an unrecognized
ipRouteIfIndex. When setting this
object via SNMP, the ipRouteIfIndex
value can only assume an appropriate
value of IfIndex defined for a
particular device type.
Objects that will be set to the default
value if not specified in the Set PDU
used to add a route:
ipRouteMetric1 – Defaults to 1 hop.
ipRouteType – Defaults to indirect.
ipRouteMask – Defaults to what is
specified in the MIB description.
Objects that are not used by this unit:
ipRouteMetric2, ipRouteMetric3,
ipRoutemetric4, ipRoutemetric5 –
Default to –1.
ipRouteNextHop Defaults to 0000
ipRouteNextHop – Defaults to 0.0.0.0.
Do not specify the following read-only
objects in the Set PDU used to add a
route:
ipRouteProto – Set to netmgmt(3) by
the software. May have the following
values:
other(1) – Temporary route added
by IP.
local(2) – Route added or changed
due to User configuration.
netmgmt(3) – Route added or
changed by SNMP set.
icmp(4) – Route added or changed
by ICMP.
rip(8) – Route added or changed
by RIP (or similar proprietary
protocol).
ipRouteAge – Reflects the value of
the time-to-live for the route (in
seconds). Defaults to 999 (permanent
route).
ipRouteInfo – Unused; set to {0, 0}.